Bbr16 Power Limitation - Daikin ERLA-DV17 Installer's Reference Manual

Table of Contents

Advertisement

6.6.4 BBR16 power limitation

ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
Example
If the configuration is as follows: Power limitation level does NOT allow operation
of backup heater (step 1).
Then power consumption is limited as follows:
P
h
c
b
a
A
B
P
Produced heat
h
C
Consumed energy
e
A Outdoor unit
B Backup heater
a Limited outdoor unit operation
b Full outdoor unit operation
c Backup heater step 1 turned ON
INFORMATION
Restriction: BBR16 settings are only visible when the language of the user interface is
set to Swedish.
NOTICE
2 weeks to change. After you activated BBR16, you only have 2 weeks to change its
settings (BBR16 activation and BBR16 power limit). After 2 weeks, the unit
freezes these settings.
Note: This is different from the permanent power limitation, which is always
changeable.
Use the BBR16 power limitation when you must comply with BBR16 regulations
(Swedish energy regulations).
You can combine the BBR16 power limitation with the other kW power
consumption controls. If you do so, the unit uses the most restrictive control.
P
i
a
BBR16
P
Power input
i
t Time
BBR16 BBR16 limit level
a Power limitation active
b Actual power input
Setup and configuration
No additional equipment needed.
C
e
b
t
6
Application guidelines
|
Installer reference guide
61

Advertisement

Table of Contents
loading

Table of Contents