14.2 Yearly maintenance

14.2.1 Yearly maintenance outdoor unit: overview

14.2.2 Yearly maintenance outdoor unit: instructions

14.2.3 Yearly maintenance indoor unit: overview

14.2.4 Yearly maintenance indoor unit: instructions

ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
Check the following at least once a year:
Heat exchanger
Heat exchanger
The heat exchanger of the outdoor unit can get blocked up due to dust, dirt,
leaves, etc. It is recommended to clean the heat exchanger yearly. A blocked heat
exchanger can lead to too low pressure or too high pressure leading to worse
performance.
Water pressure
Magnetic filter/dirt separator
Water pressure relief valve
Relief valve hose
Pressure relief valve of the domestic hot water tank
Switch box
Descaling
Chemical disinfection
Pressure reducing valve of the domestic hot water tank kit
Temperature and pressure relief valve
Water pressure
Keep water pressure above 1 bar. If it is lower, add water.
Magnetic filter/dirt separator
a
b
c
d
a Screw connection
b Magnetic sleeve
c Drain valve
d Drain cap
The yearly maintenance of the magnetic filter/dirt separator consists of: