May 2004
16.5

Data Display - IW

To enter the DATA DISPLAY screens, push the LIFECYCLES button again. This will
enable the out of balance switch to be tested, as well as giving access to the Detailed
Fault Codes and User Warning Faults. One of three displays will appear in the screen.
Use the buttons on the bottom of the display screen to toggle between these displays.
Options, up or down.
The Warning Status screen will display the
last USER WARNING FAULT that occurred
and will show at what part of the cycle it
occurred.
The User Warning Faults are as follows:
• No Taps
• Overloaded
• Out Of Balance
• Over Suds or water still in the machine
during spin
• No Hot Water
• No Cold Water
• Agitate Overloaded
The Machine Status screen displays the
status of the diverter and the out of balance
switch. It also displays the size setting of
the
machine,
and
the
thermistor
temperature.
HVDC is for on line testing in the factory.
Target temp is the temperature selected.
T is the actual temp of the inlet chamber
water.