6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
Parts name
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
No.
Parts name
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (5P)
8
Compressor
9
COIL FOR P.M.V.
10
Coil for 4-way valve
Type
RPG-240-25A
AC220~240V, 25W
( - )
10kΩ at 25°C
( - )
10kΩ at 25°C
Output (Rated) 1W, 16 poles, DC12V
24BYJ48-HTP
Type
CH-69-Z-T
L = 19mH, 10A
ICF-140-43-4R
DC140V, 43W
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
62kΩ (20°C)
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
10kΩ (25°C)
20A, AC250V
ASM89D16UFZ
3-phases 4-poles 690W
DC12V
CAM-MD12TCTH-5
AC220-240V
SQA2522G-000352
– 17 –
FILE NO. SVM-15008