Syphon Removal; Diverter Valve Motor (If Fitted); Diverter Valve (If Fitted) - Worcester 41-311-67 Installation, Commissioning And Servicing Instructions

Wall hung rsf gas fired condensing boiler
Table of Contents

Advertisement

6.8.15 SYPHON REMOVAL

Removal of the syphon assembly will give
access to the Auto Air Vent.
To release the syphon from the sump:
1. Disconnect the discharge hose at the plumbing
manifold.
2. Using a screwdriver, disengage the retaining clip on
top of the syphon.
3. Pull the syphon towards you and remove the
complete assembly.
3.
1.
Fig. 109 Syphon removal
6 720 644 743a (2010/10)
2.
6720644743-28.1Wo

6.8.16 DIVERTER VALVE MOTOR (IF FITTED)

B Connect electrical power to the appliance.
B Enter the service mode to ensure that the diverter
valve is in the mid position (there is no need to drain
the appliance).
B Electrically isolate the appliance.
B Remove diverter valve cover, if fitted.
B Disconnect the electrical connector from the diverter
valve motor.
1. Pull the motor assembly towards you.
The assembly will slide free from the valve.
B To fit the new diverter valve motor, slide the body into
the housing.
B Ensure that "H" section of the motor actuator is fitted
correctly into valve body.
B Re-connect the electrical connection.
B Re-fit the protective cover (if available).
2.
1.
Fig. 110 Diverter valve and motor

6.8.17 DIVERTER VALVE (IF FITTED)

B Ensure the appliance has been fully drained.
B Disconnect the electrical connector from the diverter
valve motor.
B Remove the diverter valve cover, if fitted.
2. Undo the two screws holding the valve to the plastic
housing.
3. Withdraw the valve and clean the valve chamber if
necessary.
B To refit, follow the above in reverse.
B Ensure any seals that have been disturbed are
renewed.
SERVICE AND SPARES
3.
6720644743-29.1Wo
59

Advertisement

Table of Contents
loading