GENERAL TECHNICAL DATA
BRAT2 without hydronic kit
Cooling capacity
Power consumption
EER
Cooling capacity
Power consumption
EER
ESEER
Flow-rate
Pressure drop
Flow-rate
Pressure drop
Sound power
Power supply
No. of compressors
No. of circuits
Type of compressor
No. of fans
Air flow-rate
No. of system heat exchangers
Type of system heat exchanger
System water heat exchanger
content
(1) outside air 35°C evaporator water IN/OUT 23/18°C
(2) outside air 35°C evaporator water IN/OUT 12/7°C
(3) maximum and minimum operating pressure refer to activation of the pressure switches
(4) sound power based on measurements performed in accordance with ISO 9614 and Eurovent 8/1
Performance in accordance with EN 14511:2013
BRAT2 with hydronic kit
Cooling capacity
Power consumption
EER
Cooling capacity
Power consumption
EER
ESEER
Flow-rate
Available pressure head
Flow-rate
Available pressure head
Sound power
Power supply
No. of compressors
No. of circuits
Type of compressor
No. of fans
Air flow-rate
No. of system heat exchangers
Type of system heat exchanger
System water heat exchanger
content
(1) outside air 35°C evaporator water IN/OUT 23/18°C
(2) outside air 35°C evaporator water IN/OUT 12/7°C
(3) maximum and minimum operating pressure refer to activation of the pressure switches
(4) Sound power based on measurements performed in accordance with ISO 9614 and Eurovent 8/1
Performance in accordance with EN 14511:2013
14
BRAT2 - BRAN2 EN
0021 0025 0031 0041 0021 0025 0031 0041 0051 0061 0071 0091 0101 0121
1
[kW]
7,71
9,50
11,5
1
[kW]
2,18
2,71
3,73
1
3,54
3,50
3,09
2
[kW]
5,74
7,03
8,68
2
[kW]
2,10
2,60
3,53
2
2,73
2,70
2,46
1
3,31
3,32
3,06
1
m
3
/h
1,33
1,63
1,98
1
kPa
13
15
16
2
m
3
/h
0,99
1,21
1,49
2
kPa
7
8
9
4
[dBA]
66
66
66
V-N/Ph-Hz
230-1N-50
1
1
1
1
1
1
1
1
1
1
[m
3
/h]
3000 3400 3400 6450 3000 3400 3400 6450 6000 6350 6800 6800 10200 10200
1
1
1
l
2
2
2
0021 0025 0031 0041 0021 0025 0031 0041 0051 0061 0071 0091 0101 0121
1
[kW]
7,76
9,56
11,6
1
[kW]
2,10
2,62
3,63
1
3,69
3,65
3,20
2
[kW]
5,77
7,08
8,73
2
[kW]
2,05
2,54
3,44
2
2,82
2,79
2,54
1
3,43
3,46
3,16
1
m
3
/h
1,33
1,64
2,00
1
kPa
59
50
40
2
m
3
/h
0,99
1,22
1,50
2
kPa
72
66
59
[dBA]
66
66
66
V-N/Ph-Hz
230-1N-50
1
1
1
1
1
1
1
1
1
[m
3
/h]
3000 3400 3400 6450 3000 3400 3400 6450 6000 6350 6800 6800 10200 10200
1
1
1
l
2
2
2
15,0
7,70
9,0
11,64 15,7
4,44
2,11
2,51
3,49
4,61
3,39
3,65
3,58
3,34
3,40
11,4
5,72
7,10
8,76
11,8
4,16
2,06
2,46
3,24
4,32
2,74
2,77
2,89
2,70
2,74
3,21
3,43
3,57
3,26
3,30
2,59
1,32
1,55
2,00
2,70
31
13
14
16
34
1,96
0,98
1,22
1,51
2,04
18
7
8
9
19
69
66
66
66
69
1
1
1
1
1
1
1
1
1
1
Scroll
2
1
1
1
2
1
1
1
1
1
PLATE
2
2
2
2
2
15,1
7,75
9,1
11,70 15,8
4,30
2,03
2,43
3,38
4,49
3,51
3,82
3,73
3,46
3,52
11,5
5,75
7,15
8,81
11,9
4,09
2,01
2,39
3,16
4,23
2,81
2,86
2,99
2,79
2,81
3,31
3,56
3,73
3,37
3,40
2,60
1,33
1,56
2,01
2,72
37
60
53
39
33
1,98
0,99
1,23
1,52
2,05
51
72
66
59
50
69
66
66
66
69
1
1
1
1
1
1
1
1
1
1
Scroll
2
1
1
1
2
1
1
1
1
1
PLATE
2
2
2
2
2
I A
17,9
20,5
25,1
28,4
35,1
4,97
5,87
7,53
9,14
9,95
3,61
3,50
3,34
3,11
3,53
13,3
15,6
19,0
21,6
26,6
4,78
5,38
6,81
8,24
9,08
2,79
2,89
2,79
2,62
2,93
3,18
3,39
3,25
3,08
3,42
3,09
3,53
4,32
4,89
6,04
36
35
39
39
41
2,29
2,68
3,27
3,71
4,57
20
20
22
22
23
69
69
74
74
76
400-3N-50
1
1
1
1
1
1
1
1
1
1
2
2
2
2
3
1
1
1
1
1
2
3
3
3
4
18,0
20,7
25,3
28,6
35,3
4,81
5,73
7,31
8,94
9,67
3,74
3,61
3,46
3,20
3,65
13,4
15,7
19,1
21,7
26,8
4,69
5,27
6,63
8,07
8,87
2,86
2,98
2,88
2,69
3,02
3,29
3,51
3,36
3,17
3,53
3,10
3,56
4,35
4,92
6,07
26
23
41
34
56
2,30
2,70
3,29
3,73
4,61
49
47
71
66
87
69
69
74
74
76
400-3N-50
1
1
1
1
1
1
1
1
1
1
2
2
2
2
3
1
1
1
1
1
2
3
3
3
4
U
40,6
12,9
3,15
31,5
11,9
2,64
3,11
6,99
42
5,42
25
76
1
1
3
1
4
40,9
12,6
3,24
31,8
11,8
2,70
3,20
7,03
43
5,47
79
76
1
1
3
1
4