"DRY" ( ) Operation
How it works?
Power failure during
operation
Clicking Sound
Clicking sound is
heard from the
air conditioner
Remote Contro Unit
OI-378-15EG
Special Remarks
•
Once the room temperature reaches the level that was set, the unit
repeats the cycle of turning on and off automatically.
•
During DRY operation, the fan speed is automatically set to LOW or
VERY LOW; the fan speed then switches back and forth between LOW
(for 20 seconds) and VERY LOW (for 10 seconds).
•
''DRY'' operation is not possible if the indoor temperature is 15°C or less.
•
In the event of power failure, the unit will stop. When the power is
resumed, the unit will restart automatically after three minutes.
•
In cooling operation, any plastic parts may expand or shrink due to a
sudden temperature change. In this event, a clicking sound may occur.
This is normal, and the sound will soon disappear.
•
The remote control unit sends the setting condition to the air conditioner
regularly at three minute intervals.
15