9-5. If a sensor is defective.

9-5-1. Indoor coil temp. thermistor (TH1) is defective.
• Operation lamp on front side of
indoor unit is flashing on and off. (*)
NOTE
Alarm Signal (*)
Operation lamp on the front side of the indoor unit will flash on and off when the indoor coil thermistor is defective.
At the same time the outdoor unit will stop. Indoor unit will operate only for ventilation.
9-5-2. Room temp. thermistor (TH2) is defective.
A. Open
When thermistor opens, the air conditioner will be in the following conditions as the controller tries to detect
extremely low room temperature.
In Cooling mode:
B. Short
When thermistor is short, the air conditioner will be in the following conditions as
the controller tries to detect extremely high room temperature.
In Cooling mode:
NOTE
Definition of Open or Short Circuit of Sensor (Thermistor)
Open ... A lead wire is broken or disconnected or the circuit inside the temperature sensor is open .
Short ... The protective cover of a lead wire has been damaged, and the exposed wire is touching another metal
part, or both lead wires have become exposed and are touching each other. Alternatively, the circuit
inside the temperature sensor is closed.
YES
The air conditioner soon stops and will not start again. (Thermo.OFF) Neither outdoor fan
nor compressor runs.
The air conditioner continues to operate (Thermo.ON). Both
the outdoor fan and compressor do not stop. As a result,
the room becomes too cold.
• Thermistor (TH1 ) is defective.
(That is, sensor is SHORT.)
• Replace thermistor.