5
|
About the units and options

5.3.3 Possible options for the outdoor unit

5.3.4 Possible options for the indoor unit

Installer reference guide
28
The booster heater must be located above the heat exchanger coil.
NOTICE
Performance. Performance data for third-party tanks CANNOT be provided, and
performance CANNOT be guaranteed.
NOTICE
Configuration. Configuration of a third-party tank depends on the size of the heat
exchanger coil of the tank. For more information, see
Mounting stand (EKMST1, EKMST2)
In colder regions where heavy snowfall can occur, it is recommended to install the
outdoor unit on a mounting frame. Use one of the following models:
EKMST1 with flange feet: to install the outdoor unit on a concrete foundation
where drilling is allowed.
EKMST2 with rubber feet: to install the outdoor unit on foundations where
drilling is not allowed or possible, such as flat roofs or pavements.
For installation instructions, see the installation manual of the mounting stand.
Multi-zoning wired controls
You can connect the following multi-zoning wired controls:
Multi-zoning base unit 230 V (EKWUFHTA1V3)
Digital thermostat 230 V (EKWCTRDI1V3)
Analogue thermostat 230 V (EKWCTRAN1V3)
Actuator 230 V (EKWCVATR1V3)
For installation instructions, see the installation manual of the control, and the
addendum book for optional equipment.
Room thermostat (EKRTWA, EKRTR1)
You can connect an optional room thermostat to the indoor unit. This thermostat
can either be wired (EKRTWA) or wireless (EKRTR1).
For installation instructions, see the installation manual of the room thermostat
and addendum book for optional equipment.
Remote sensor for wireless thermostat (EKRTETS)
You can use the remote indoor temperature sensor (EKRTETS) only in combination
with the wireless thermostat (EKRTR1).
For installation instructions, see the installation manual of the room thermostat
and the addendum book for optional equipment.
Digital I/O PCB (EKRP1HBAA)
The digital I/O PCB is required to provide following signals:
Alarm output
Space heating/cooling On/OFF output
Changeover to external heat source
4
"Domestic hot
water" [
 190].