WatchGuard
XTM 1050
Hardware Guide
XTM 1050
XTM 1050 with Fiber Card
XTM 1050 with 10 Gb Interface Module
NX3CE12

Advertisement

Table of Contents
loading

Summary of Contents for Watchguard NX3CE12

  • Page 1 WatchGuard XTM 1050 Hardware Guide XTM 1050 XTM 1050 with Fiber Card XTM 1050 with 10 Gb Interface Module NX3CE12...
  • Page 2 Copyright© 1998–2011 WatchGuard Technologies, Inc. All rights reserved. WatchGuard, the WatchGuard logo, LiveSecurity, and any other mark listed as a trademark in the “Terms of Use” portion of the WatchGuard Web site that is used herein are either registered trademarks or trademarks of WatchGuard Technologies, Inc.
  • Page 3: Hardware Specifications

    Our security subscriptions give you fully integrated protection from spyware, spam, viruses, worms, trojans, web-based exploits, and blended threats. From firewall and VPN protection to secure remote access, WatchGuard XTM devices support a broad range of network environments.
  • Page 4: Package Contents

    Hardware Specifications Processor Dual 2.33 GHz Quad Core Intel Xeon Memory: Flash 1 GB Memory: RAM 4 GB Power supply 100-240 VAC Autosensing Dimensions D=20.1” (51.0 cm) W=16.9” (43.0 cm) H=3.5” (8.8 cm) Weight 33.5 lbs (15.2 Kg) WatchGuard XTM 1050...
  • Page 5: Interface Specifications

    Hardware Specifications Interface Specifications Network • 14x GbE Copper RJ45, 1000Base-T, 100Base-TX, or 10 Base-T (10/100/ 1000Mbps) interfaces • Includes 10x fixed ports, 4x on removable module • Interfaces 12 and 13 are labeled Management Ethernet Fiber • 4 GbE SFP Module replaces standard 4x Copper module Option •...
  • Page 6: Hardware Description

    Dual USB Port Connect a USB storage device to use for USB backup and restore, or to store a support snapshot. For more information about USB functions, see the Fireware XTM WatchGuard System Manager Help or Fireware XTM Web UI Help.
  • Page 7 Hardware Specifications A close-up of the right side of the XTM 1050: The indicators and connectors are: Interface ports The XTM 1050 has a total of 14 interface ports. Interface ports have standard RJ45 connectors. Interface ports 0 - 11 are labeled 0, 1, 2, 3...11. Interface ports 12 and 13 are not numbered.
  • Page 8 The Connection LED is blue when the interface operates at 10 Gb. Note After you install the 10 Gb Interface Module, interfaces 10 and 11 are still visible in the device configuration, but are unused, even if you configure them in the management software. WatchGuard XTM 1050...
  • Page 9: Rear View

    AC receptacles on each power supply Each AC receptacle accepts a detachable AC power cord supplied with the XTM 1050. Each power supply for the device is a WatchGuard standard auto-sensing AC power supply. Replaceable power supply and power switch There are two power supplies on the XTM 1050, each with their own power indicator light.
  • Page 10: Rack Mount Instructions

    Hardware Specifications Rack Mount Instructions Each WatchGuard XTM 1050 device ships with a 29” rack mount kit and a set of installation instructions. When you install the XTM 1050 in a rack, make sure you consider: Elevated Operating Ambient Temperature If you install the XTM 1050 in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient.
  • Page 11: Safety Notices

    Hardware Specifications Safety Notices All WatchGuard products are designed and tested to meet strict safety requirements. These requirements include product safety approvals and other global compliance standards. Read these instructions carefully before you operate the product, and refer to them as needed for continued safe operation of your product.
  • Page 12 With this button, you can increase the value of a selected item, or move up in a group of menu entries. Bottom Left (Down Arrow) button With this button, you can decrease the value of a selected item, or move down in a group of menu entries. WatchGuard XTM 1050...
  • Page 13 Hardware Specifications Use the LCD Interface in Normal Mode The XTM 1050 automatically boots in normal mode, unless you specifically put it in safe mode. To operate, it uses the installed Fireware XTM OS and the rules in the configuration file you have saved to the device. You can use the four arrow buttons to see information about the device on the LCD screen.
  • Page 14 2. Press the Down Arrow button to see the options below that menu item. 3. Press the Right Arrow button to scroll through the items in the Hardware Monitor menu until CPU temperature appears. 4. Press the Up Arrow button to return to the main category level. WatchGuard XTM 1050...
  • Page 15: Legal And Regulatory Information

    WatchGuard Technologies, Inc. (“WatchGuard”) and you agree as set forth below or on the reverse side of this card, as applicable: 1.
  • Page 16 WITH REGARD TO ANY PRODUCT WILL IN NO EVENT EXCEED THE PURCHASE PRICE PAID BY YOU FOR SUCH PRODUCT. THIS SHALL BE TRUE EVEN IN THE EVENT OF THE FAILURE OF ANY AGREED REMEDY. IN NO EVENT WILL WATCHGUARD BE...
  • Page 17: Declaration Of Conformity

    Legal and Regulatory Information Declaration of Conformity Hardware Guide...
  • Page 18: Fcc Certification

    This device must accept any interference received, including interference that may cause undesired operation. CE Notice The CE symbol on your WatchGuard Technologies equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU).
  • Page 19: Rohs Statement

    Legal and Regulatory Information People’s Republic of China Electronic Industry Standard This table is presented in accordance with SJ/T11364-2006, Marking for Control of Pollution Caused by Electronic Information Products, implemented in November 2006. RoHS Statement The member states of the European Union approved directive 2002/95/EC, Restrictions of Hazardous Substances (“RoHS directive”‘) that becomes valid on July 1, 2006.
  • Page 20: Weee Statement

    WEEE statutes, and that the recovery of our product per the specific EU country legislative requirements is seamless for our product’s end users. If you have a WatchGuard product that is at its end of life and needs to be disposed of, please contact WatchGuard Customer Care Department at: U.S. Customers: 877.232.3531 International Customers: +1.206.613.0456...
  • Page 21 Legal and Regulatory Information Licensing Some components of the WatchGuard System Manager software are distributed with source code covered under one or more third party or open source licenses. You can find full licensing information in the product documentation on our public web site at www.watchguard.com/help/documentation. We include below the full text of the GNU General Public License.
  • Page 22: Gnu General Public License ("Gpl")

    To prevent this, we have made it clear that any patent must be licensed for everyone's free use or not licensed at all. The precise terms and conditions for copying, distribution and modification follow. WatchGuard XTM 1050...
  • Page 23: Terms And Conditions For Copying, Distribution, And Modification

    Legal and Regulatory Information Terms and Conditions for Copying, Distribution, and Modification 1. This License applies to any program or other work which contains a notice placed by the copyright holder saying it may be distributed under the terms of this General Public License. The "Program", below, refers to any such program or work, and a "work based on the Program"...
  • Page 24 License, they do not excuse you from the conditions of this License. If you cannot distribute so as to satisfy simultaneously your obligations under this License and any other pertinent obligations, then as a consequence you may not distribute the WatchGuard XTM 1050...
  • Page 25 Legal and Regulatory Information Program at all. For example, if a patent license would not permit royalty-free redistribution of the Program by all those who receive copies directly or indirectly through you, then the only way you could satisfy both it and this License would be to refrain entirely from distribution of the Program. If any portion of this section is held invalid or unenforceable under any particular circumstance, the balance of the section is intended to apply and the section as a whole is intended to apply in other circumstances.
  • Page 26 Legal and Regulatory Information WatchGuard XTM 1050...

This manual is also suitable for:

Xtm 1050

Table of Contents