  • Page 1 INSTRUCTION MANUAL CPARLENE ® Blood Pressure Simulator LF03204...
  • Page 2 Figure 1 Figure Figure 2 About the Simulator About the Simulator About General Instructions for Use The Nasco Healthcare Blood Life/form The Nasco Life/form Blood Pressure Simulator is designed for years of The Na The Nasco Blood Pressure Simulator is designed for years of ®...
  • Page 3 Under the display window are three buttons: Menu, Gap, and Calibrate. (See with the sphygmomanometer cuff and gauge assemb the plug that is at the end of the the Nasco Healthcare Blood the end of the wire which extends from the simulated arm assembly. Insert the end figure 5.) The systolic pressure is set by pressing the Menu key once.
  • Page 4 Palpable Pulse Feature too hard can damage the pulse The Nasco Healthcare Blood The pulse in the wrist will begin when the electronic box is turned on. During The pulseless setting will also turn off the sounds in the arm. The pulse will feature.
  • Page 5 Use of the Simulator Make sure the cable from the blood pressure arm is properly connected to the electronic box and the palpation feature is in the “PULSE ON” mode. A pulseless condition can be sim- ulated by switching your unit to the “pulseless”...
  • Page 6 This is the to level 7 (the highest volume). diastolic blood pressure. Compare the results of reading Using the Nasco Healthcare the systolic and diastolic blood pressures on the gauge with the Blood Pressure Simulator respective settings on the simula- First, verify that the pressure tor.
  • Page 7: Calibration Procedures

    Example: If the blood es in the Korotkoff phases being pressure reading was taken presented. The Nasco Healthcare and the sounds started at 148 Blood Pressure Simulator is pro- mmHg, then the offset is +2. grammed to demonstrate the...
  • Page 8 Use of the Simulator instrument, carefully cut the pres- With the arrow down key, set sure line of the correction to –2. Press the the sphygmomanometer about 2” from the gauge. (See figure Menu key again and the message 14.) Take the T-fitting and insert it “CALIBRATION COMPLETE”...