Summary of Contents for Nasco Healthcare DANi LF04500

  • Page 1 INSTRUCTION MANUAL DANi Patient Care Trainer LF04500/LF04500M Patient Skills Trainer LF04502/LF04502M Patient Simulator LF04504/LF04504M Patient Simulator, Export LF04504EX/LF04504MEX...
  • Page 2: Table Of Contents

    Table of Contents About the Simulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 List of Components .
  • Page 3: About The Simulator

    About the Simulator Nasco Healthcare DANi Teen & Young Adult is a comprehensive male/female patient care trainer for medical simulation . Evolving from our KERi full- ™ body manikins, it has a more realistic look and feel accurately representing the human anatomy . Weight is distributed to represent a real patient for lifting and carrying .
  • Page 4 About the Simulator LF04500/LF04500M: DANi Teen & Young Adult • Clothing Changes Patient Care Trainer • Bed Baths • Eye Irrigation & Optic Drops • Superior Range of Motion • Dental Care • Enhanced Full Body Aesthetics • Ear Canal Irrigation •...
  • Page 5 LF04504/LF04504M: DANi Teen & Young Adult • Injection Sites (arms, thigh, right side buttocks supporting IM and sub-cutaneous injections) Patient Simulator (includes monitors) • Gastrostomy Procedures (lavage, gavage, tube placement) LF04504EX/LF04504MEX: DANi Teen & Young Adult • Nasogastric Tube Procedures (lavage, gavage, tube placement, Patient Simulator, Export (excludes monitors) feeding, suctioning) •...
  • Page 6 DANi Teen & Young Adult Training Solution LF04504/EX LF04500 / LF04500M LF04502 / LF04502M LF04504M / LF04504MX Model Advanced Patient Care Trainer Advanced Patient Skills Trainer Advanced Patient Simulator Feature Set Capability General Superior Range of Motion ✔ ✔ ✔ Enhanced Aesthetics ✔...
  • Page 7: List Of Components

    List of Components DANi Teen & Young Adult Patient Care Trainer • Female Genitalia, SANE (LF04514, Light/LF04514M, Medium) LF04500/LF04500M DANi Teen & Young Adult Patient Simulator • Male Genitalia Foreskins, Pack of 3 (LF000843 G, Light/ LF04504/LF04504M (includes monitors) LF00842 G, Medium) DANi Teen &...
  • Page 8: Arms / Joints / Legs / Eyes / Oral Hygiene

    Set Up Arms / Joints / Legs / Eyes / Oral Hygiene Note: All Versions of DANi come packaged with Eyes the normal eyes, and female genitalia installed . The Patient Skills Trainer and Simulator come with All versions of DANi lungs, stomach, and other internal reservoir bags come with 3 sets of installed .
  • Page 9: Ear Care / Bath & Washing / Tracheostomy Care

    Set Up Ear Care / Bath & Washing / Tracheostomy Care Ear Care Tracheostomy Care Both ears may be Suctioning, dressing changes, tracheostomy tube irrigated . Using water to placement, and cuff inflation may be practiced perform ear irrigation is on the simulator .
  • Page 10: Lavage / Gavage / Suctioning / Carotid Pulse

    Set Up Lavage / Gavage / Suctioning / Nasogastric / Carotid Pulse Oral and Nasal Lavage, To remove the Stomach Gavage, and Suctioning Reservoir Bag: Access to the stomach 1 . Remove the head by is provided through the disconnecting the mouth and both nostrils .
  • Page 11: Nasogastric / Lung Bag And Stomach Bag

    . Pump Spray Lubricant provided (See Figure Note: Use Nasco Healthcare’s Pump Spray Lubricant 15) . NG tubes should to lubricate airway devices before use . be well lubricated and force should not be...
  • Page 12: Intubatable Head

    Preferred bag . Each bag will cause visual chest rise in the correct anatomical location to indicate effective Note: Use Nasco Healthcare’s Pump Spray Lubricant and ineffective intubation styles . Jaw thrust is to lubricate airway devices before use .
  • Page 13: Ostomy Care

    Set Up Ostomy Care Ostomy Care Colostomy and ileostomy care can be practiced on all DANi models, including stoma dilation, cleaning, and ostomy bag changing procedures . Irrigation can be practiced . Irrigation tubes should be well lubricated prior to insertion . After completion of the exercises, the stomas can be rinsed with warm water to remove any residual lubricant .
  • Page 14: Gastrostomy Care Lavage And Gavage

    Set Up Gastrostomy Care Lavage and Gavage Gastrostomy Care Lavage and Gavage To attach the bag: 1 . Push the coupler body (with bag attached) A flanged hole simulating onto the coupler insert (part with the black an abdominal incision O-ring) that is protruding from the underside of for the insertion of a the gastrostomy inside the upper torso of the...
  • Page 15: Male Catheterization

    Foley catheter . Note: To apply the foreskin, apply the included pump Nasco Healthcare spray lubricant to the glans and slide the foreskin in recommends use of place . To prepare for catheterization exercises: Fig 31.
  • Page 16: Foreskin Application / Prostate Examination

    Set Up Foreskin Application / Prostate Examination Foreskin Application Prostate Examination Place the foreskin over the gland by lubricating the There are five prostates gland with baby powder and placing the foreskin included with your over the glans . The placement of the foreskin can simulator .
  • Page 17: Female Catheterization

    Note: Special care should be taken when using a fit into the open genital Foley catheter . Nasco Healthcare recommends use area of the pelvis . (See Figure 36) . of 16 French Foley catheters . use of this size will avoid the possibility of leakage .
  • Page 18: Enema Administration

    Set Up Set Up Enema Administration Female Cervical Exam Enema Administration Female Cervical Examination Features included with LF04502/LF04502M, Features included with LF04502/LF04502M, LF04504/LF04504M, and LF04504EX/LF04504MEX . LF04504/LF04504M, and LF04504EX/LF04504MEX . Enema Administration can only be practiced on the The female genital insert allows for douching . Only female genital insert .
  • Page 19: Suprapubic And Urinary Catheterization

    Set Up Suprapubic and Urinary Catheterization Suprapubic Catheterization Note: Use distilled water or follow instructions on Features included with LF04502/LF04502M, the Simulated Urine . LF04504/LF04504M, and LF04504EX/LF04504MEX . 7 . Lubricate the catheter being used with the To prepare the simulator for suprapubic Pump Spray Lubricant provided .
  • Page 20: Blood Pressure Arm

    Set Up Blood Pressure Arm Blood Pressure Arm 2 . Attach this end of the Features included with LF04502/ pressure line to the LF04502M, LF04504/LF04504M, female luer fitting and LF04504EX/LF04504MEX . assembled at the top of the electronic Installing the Batteries control unit marked CUFF .
  • Page 21 Set Up Blood Pressure Arm Setting Systolic and Diastolic Pressure Setting the Heart Rate 1 . Press the Menu Key once . 1 . Press the Menu Key a third time . 2 . The “Set SYSTOLIC” 2 . The “Set HEARTRATE” pressure menu will menu will display in display in the Electronic...
  • Page 22 Set Up Blood Pressure Arm Setting the Palpable Pulse Setting the Auscultatory Gap This function is included to simulate the gap that The palpable pulse is sometimes present between phases 1 and 2 in is found at the radial which no audible sound is noted . location .
  • Page 23 Set Up Blood Pressure Arm Performing a Blood Pressure Calibration Procedures 1 . Verify the pressure line tubing from the 1 . Follow the setup procedures . sphygmomanometer and the audio line from the arm are properly connected to the electronic 2 .
  • Page 24 Set Up Blood Pressure Arm Preparing Your Sphygmomanometer for Use with Blood Pressure Simulator In the event the supplied sphygmomanometer would cease to operate, any standard sphygmomanometer can be adapted for use with the blood pressure simulator . It is recommended that a child size cuff continue to be used .
  • Page 25: Iv And Injection Arm

    Set Up IV and Injection Arm IV and Injection Arm 2 . Close the clamp on the IV tubing and pour the Features included with LF04502/LF04502M, synthetic blood into one of the provided fluid LF04504/LF04504M, and LF04504EX/LF04504MEX . supply bags . This will be IV Bag A . Fill to 500 cc maximum .
  • Page 26: Injectable Arm

    Set Up Injectable Arm Preparing the Arm for Intravenous Infusions Proof of proper procedure will be evidenced by the flow of fluid from IV Bag A . Control flow rate with the clamp on IV Bag A . A third IV Bag (not supplied) 1 .
  • Page 27 Set Up Injectable Arm User Help Guide for the Injectable Training Arm Care and Maintenance 1 . Follow procedures and ensure clamps are open After each use of the Injectable Training Arm, follow on appropriate fluid supply/IV bags and/or these procedures: shoulder tubes .
  • Page 28 Set Up Injectable Arm To prevent causing harm to the Injectable Leg Skin Replacement Training Arm: 1 . Remove the eight screws retaining the hip joint 1 . Use distilled water rather than alcohol, Betadine to the leg . (See Figure 71) . ®...
  • Page 29 Set Up Injectable Arm Moulage Intramuscular Injections DANi comes with self- Intramuscular injections may be performed in adhesive moulage that inserts at the left hip, right thigh, at both deltoids of simulates self-harm the standard arms, and left deltoid of the injectable wounds .
  • Page 30: Auscultation

    Set Up Auscultation Auscultation 1 . Locate your SmartScope and Remote Control ™ Features included with LF04504/LF04504M, and with LCD display . LF04504EX/LF04504MEX . 2 . Locate included “AA” and “AAA” batteries . The auscultation feature duplicates heart and lung conditions selected by the instructor via wireless 3 .
  • Page 31 Set Up Auscultation Listening to Selected Heart and Lung Sounds Using the Amplified Speaker (purchased separately LF01189U) 1 . Follow the instructions above to activate remote control, SmartScope , and select desired sounds . 1 . Locate the SmartScope and speaker cord ™...
  • Page 32: Anterior Heart Sites

    Set Up Anterior Heart Sites Second left intercostal space Second right (pulmonic) intercostal space (aortic) Third left intercostal space (Erb’s point) (lower left Fourth left sternum) intercostal space Apex Erb’s Point Aortic Second Pulmonic Second Fourth Left Third Left Lower Left Right Intercostal Left Intercostal Intercostal...
  • Page 33: Anterior / Posterior Lung Sites

    Set Up Anterior / Posterior Lung Sites First right intercostal Tracheal Site space First left intercostal Lower space anterior Upper posterior Lower posterior Midaxillary Midaxillary Lower Posterior Lung Sites First Left & Right Upper Posterior Tracheal Site Two Midaxillary Sites Intercostal Sites Lung Sites 2 Lower Anterior Sites...
  • Page 34: Pressure Injury Wounds

    Set Up Set Up Pressure Injury Wounds Edema Pressure Injury Wounds Edema Features included with LF04502/LF04502M, Features included with LF04502/LF04502M, LF04504/LF04504M, and LF04504EX/LF04504MEX . LF04504/LF04504M, and LF04504EX/LF04504MEX . Pressure wound identification and care may be performed by using the included foot wound sleeve . Five wounds are included: Stages 1-4 and a deep Edema identification may be performed by using tissue wound .
  • Page 35: Cpr Measuring

    Set Up CPR Measuring CPR Measuring Powering on CPR Monitoring Feature Features included with LF04502/LF04502M, LF04504/LF04504M, and LF04504EX/LF04504MEX . 1 . To power on the CPR monitoring feature, Apple or Android Device access the “ON/OFF” button through the The CPR Plus application enables accurate and genital opening in the effective training using CPR Add-on Student or pelvis (See Figure 87) .
  • Page 36: Identifying Parts And Consumables

    Set Up Identifying Parts and Consumables Skin...
  • Page 37 Set Up Identifying Parts and Consumables Tattoo Sleeve LF04521 Torso Skin, Light LF04527 Wound, Cut LF04521M Torso Skin, Medium LF04522 Wig, Multicolored LF04526 Wound, Bruise Earrings LF04523 Wig, Black LF04525 Wig, Brown LF00843 G Male Genitalia Foreskins, Pack of 3, Light LF04528 Edema, Light, Stages 1-4 &...
  • Page 38: Care And Maintenance

    Set Up Care and Maintenance Overall Care and Maintenance General Care Storage 1 . Most cleaning can be done with a soft cloth, mild In order to prepare DANi for storage perform a soap, and warm water . Avoid over washing the normal manikin breakdown procedure by removing painted areas on the manikin .