Polygon motor lock signal error
The signal remains HIGH for 200 ms (or 4times in 50msec polling) while the polygon mirror
motor is rotating.
• Polygon motor/driver board harness loose or disconnected
204
• Polygon motor/driver board defective
• Laser optics unit defective
1. Turn the machine main power off/on.
2. Replace the interface harness of the laser optics unit.
3. Replace the laser optics unit.
Beam Synchronize error
The laser synchronizing detection signal for LD is not output within 400msec after the LD unit
has turned on.
• Disconnected cable from the laser synchronizing detection unit or defective connection
• Defective laser synchronizing detector
220
• Defective LD
• Defective Main board
1. Check the connectors.
2. Replace the laser optics unit.
3. Replace the Main board.
Laser Scanning Unit thermistor error
At power on, the temperature sensor in the optics unit detected a temperature lower than
-30°C for more than 4 sec.
-or-
It detected a temperature higher than 105°C for more than 1sec.
268
• Thermistor disconnected (causes extremely low temperature reading)
• Thermistor damaged and short circuited (causes extremely high temperature reading)
1. Turn the machine's main power off, and then on.
2. Replace the thermistor.
Service Call
125