5. Service Tables
Handling Mode on
"Waste Toner full"
of the refilled AIO
"*" indicates the factory default value.
SP Mode 3
Destination
PnP ID
Serial No
Main Motor
Rotation Time
Charge Bias
Adjust of Charge
Bias
106
Sets the machine operation at "waste toner full" of the refilled AIO.
[On or Off (Default)]
Sets the destination and updates the engine setting. Do not change this setting
(Designed for Factory Use).
JPN/ NA/ EU / ASIA/ China/ TAIWAN/ KOREA
Do not change this setting (Designed for Factory Use).
Do not change this setting (Designed for Factory Use).
Displays the main motor rotation time.
Adjusts the charge bias.
[1100 to 1300 / 1200 / 20 /step]
Charge bias correction for dirty background
0: OFF (Default)
1: ON
2 to 255: not available
[0 to 255 / 0 / 1 /step]
Type E Models: RTB 5
IMPORTANT NOTE on "Clear
Engine Memory" button
Clicking the "Clear Engine
Memory" button in the SOM
(printer configuration screen)
or the SP mode will falsely
reset all the engine related
values stored in the main
board, and the machine must
be replaced.