Control Port Functions
Pin No.
Name
67
A4
68
A5
69
A6
70
A7
71
A8
72
A9
73
A10
74
A11
75
VssQ
76
A12
77
VccQ
78
A13
79
A14
80
A15
81
A16
82
A17
83
A18
84
A19
85
A20
86
VssQ
87
A21
88
VccQ
89
A22
90
A23
91
Vss
92
A24
93
Vcc
94
A25
95
BS/PTK[4]
96
RD
97
WE0/DQMLL
98
WE1/DQMLU/WE
99
WE2/DQMUL/ICIORD/PTK[6]
100
VssQ
101
WE3/DQMUU/ICIOWR/PTK[7]
102
VccQ
103
RD/WR
104
P
TE[7]/PCC0RDY/AUDSYNC
105
CS0
106
CS2
107
CS3
108
CS4/PTK[2]
109
CS5/CE1A/PTK[3]
110
CS6/CE1B
111
CE2A/PTE[4]
112
CE2B/PTE[5]
113
AFE_HC1/USB1d_DPLS/PTK[0] GAMMA_RST
114
AFE_RLYCNT/USB1d_DMNS/PTK[1]
115
VssQ
116
AFE_SCLK/USB1d_TXDPLS
117
VccQ
118
PTM[7]/PINT[7]/AFE_FS/USB1d_RCV
119
PTM[6]/PINT[6]/AFE_RXIN/USB1d_SPEED
120
PTM[5]/PINT[5]/AFE_TXOUT/USB1d_TXSE0
121
PTM[4]/PINT[4]/AFE_RDET/USB1d_TXDMNS
122
RESV/USB1d_SUSPEND
123
USB1_ovr_crnt/USBF_VBUS
124
USB2_ovr_crnt
125
RTS2/USB1d_TXENL
126
PTE[2]/USB1_pwr_en
127
PTE[1]/USB2_pwr_en
128
CKE/PTK[5]
129
RAS3/PTJ[0]
130
Reserved/PTJ[1]
131
Reserved/CAS/PTJ[2]
132
VssQ
Function Name
Function
A4
Address Bus 4
A5
Address Bus 5
A6
Address Bus 6
A7
Address Bus 7
A8
Address Bus 8
A9
Address Bus 9
A10
Address Bus 10
A11
Address Bus 11
GND
Vss for IO-port
A12
Address Bus 12
3.3V
Power Supply for IO-port
A13
Address Bus 13
A14
Address Bus 14
A15
Address Bus 15
A16
Address Bus 16
A17
Address Bus 17
A18
Address Bus 18
A19
Address Bus 19
A20
Address Bus 20
GND
Vss for IO-port
A21
Address Bus 21
3.3V
Power Supply for IO-port
A22
Address Bus 22
A23
Address Bus 23
GND
Vss
A24
Address Bus 24
1.9V
Vcc
A25
Address Bus 25
BS
Bus-cycle start(ICE)
RD
Read strobe
WE0
D7-D0 select / DQM(SDRAM)
WE1
D15-D8 select / DQM(SDRAM)
WE2
D23-D16select / DQM(SDRAM)
GND
Vss
WE3
D31-D24 select / DQM(SDRAM)
3.3V
Vcc
RDWR
Read / Write
AUDSYNC
AUD sync(ICE)
CS0
CS0 Flash Memory [32bit]
Not used
CS3
CS3 SDRAM
CS4
CS4 Decoder
Not used
Digital Gamma_RESET
GAMMA_SW
Digital Gamma correction
GND
Vss
Not used
3.3V
Vcc
Not used
Not used
Not used
Not used
Not used
USBF_VBUS
USB Function VBUS-1
USB2_ovr_crnt
USB Host over current detect
(USB Digital)
Not used
USB1_pwr_en
USB function Power enable
USB2_pwr_en
USB Host Power enable
CKE
SDRAM Clock enable
RAS3
SDRAM RAS
GAMMA_CS
Digital Gamma CS
CAS
SDRAM CAS
GND
Vss
-56-
Polarity
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[32bit]
Active L
Active L
-
H fixed
-
Active L
-
I/O
O
O
O
O
O
O
O
O
-
O
-
O
O
O
O
O
O
O
O
-
O
-
O
O
-
O
-
O
O
O
O
O
O
-
O
-
O
O
O
O
O
O
O
-
O
O
-
-
-
I
I
I
I
I
I
O
O
O
O
O
O
-

Advertisement