Optical Pats Disassemblies
c
Relay Lens-Out disassembly
1
A
Remove 2 screws
(M2.5x5) and pull the Relay Lens-Out ass'y upward.
2
B
Remove 2 screws
(M2x2) to take the Lens off from the holder.
v
Polarized Glass-In removal
1
Remove each screw (M2.5x5) and pull the Polarized Glass-In ass'y
upward.
2
Unhook the stoppers and take the glass off upward.
A
A
Fig.3-
1
* Glass should be placed as the
printed marker comes to the
upper left corner.
Fig.4-
1
-16-
Holder
Part No. is printed on
upper side.
B
Relay Lens
Part No. is printed on
upper side.
polarized glass
Phase Sheet
B
Fig.3-
2
Fig.4-