Service Procedure EF-XIII
Anode/Flue Baffle Inspection and Replacement
Collector Cover Installation Procedure
Step 1. Remove old silicone from top surface of collector flange and collector cover.
Step 2. Apply ¼" bead of Ultra Copper Silicone around entire collector flange surface.
Step 3. Carefully reinstall collector cover, tighten screws evenly.
Step 4. Allow a minimum of 6 hours before putting heater back in service.
Apply ¼" bead of Ultra
Copper Silicone around entire
collector flange surface