Bradford White EF Series Service Manual page 13

Ultra high efficiency water heaters
Table of Contents

Advertisement

Be Careful When Making Voltage Measurements or Jumping Terminals
Not to Damage or Deform Connectors or Connector Pins.
Draw Water From The T&P Valve. Compare Temperature With
Example: If temperature of sensor is 84°F, then the resistance through the sensor would be 8449 (see shaded area).
NOTE: Sensor resistance increases as the temperature falls.
°F
0
1
40
26109
25400
50
19906
19383
60
15314
14925
70
11884
11592
80
9299
9078
90
7333
7165
100
5827
5697
110
4663
4562
120
3758
3679
130
3048
2986
140
2488
2439
150
2043
2004
160
1688
1656
170
1402
1376
180
1170
1150
190
982
965
200
828
814
Proper Readings Should Be Greater Then 4800 Ohms at
Be Careful When Making Voltage Measurements or Jumping Terminals
Not to Damage or Deform Connectors or Connector Pins.
SERVICE PROCEDURE EF-I
Thermostat Circuit Testing and Replacement
APPENDIX - A
Sensor Resistance at Various Temperatures
Temperature Ohms Chart Below.
In Degrees F
2
3
4
24712
24045
23399
18876
18383
17905
14548
14180
13823
11308
11032
10763
8862
8653
8449
7000
6839
6683
5570
5446
5326
4464
4368
4274
3602
3527
3453
2925
2866
2808
2391
2344
2298
1966
1928
1891
1625
1595
1566
1351
1327
1303
1129
1110
1090
949
933
917
801
788
775
APPENDIX - B
Temperature Dial Resistance
Minimum Setting
And Less Then 50 Ohms at Maximum.
5
6
7
22771
22163
21573
17440
16990
16553
13477
13140
12812
10502
10248
1000
8250
8057
7869
6531
6383
6238
5208
5094
4982
4183
4094
4006
3382
3312
3244
2752
2697
2643
2253
2209
2166
1856
1820
1786
1537
1509
1481
1280
1257
1235
1071
1953
1035
901
886
871
762
749
737
8
9
21000
20445
16128
15715
12494
12185
9760
9526
7685
7507
6098
5961
4873
4767
3922
3839
3177
3112
2590
2538
2124
2083
1753
1720
1454
1427
1213
1191
1017
999
857
842
725
713
Page 13
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents