Bradford White EF Series Service Manual page 41

Ultra high efficiency water heaters
Table of Contents

Advertisement

Anode inspection and replacement
Heater components and stored water may be HOT when performing the following steps in
this procedure. Take necessary precaution to prevent personal injury.
Step 1. Turn off water supply and drain water heater.
Step 2. Disassemble heater per disassembly procedure on page 40.
Step 3. Locate and remove anode rods from heater (1-1/16 hex socket).
Step 4. Visually inspect anode rod. Anode rod should show signs of depletion, this is normal. If
the depletion is ½ of the original diameter (approximately ¾" diameter), replacement is
recommended. If any of the steel core of the anode is exposed, replacement is
recommended.
Step 5. Upon completion of inspection or subsequent replacement, apply Teflon tape or other
thread compound to threads of anode and reinstall into heater. Restore water supply
and check for and repair any leaks found.
Step 6. Reinstall collector cover per procedure on page 43.
Step 7. Reinstall collector insulation and control panel, reconnect control panel wire harnesses.
Step 8. Restore 120 volts to water heater and verify proper heater operation following the
instructions on the lighting instruction label or the lighting instruction located in the
installation and operating instruction manual.
Step 9. Replace surround cover on top of water heater.
Service Procedure EF-XIII
Anode/Flue Baffle Inspection and Replacement
WARNING
Page 41
Page 41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents