Download Print this page

Advertisement

Quick Links

Information and Communication
Communication Devices
E10 / S6 Power GSM /S8 GSM
Level 2.5
Repair Documentation
V 1.2
V1.2
Page 1 of 22
ICP CD ST
D. Schnoor
06/98

Advertisement

loading

Summary of Contents for Siemens E10

  • Page 1 Information and Communication Communication Devices E10 / S6 Power GSM /S8 GSM Level 2.5 Repair Documentation V 1.2 V1.2 Page 1 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 2: Table Of Contents

    Information and Communication Communication Devices Table of Contents: 1INTRODUCTION..............................2 2VCXO ....................................3 3FUSE 1A ....................................8 4FUSE 0.25 A ....................................12 5MOLEX CONNECTOR ....................................16 6RINGER ....................................20 1Introduction V1.2 Page 2 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 3: 2Vcxo

    Failure highlights are documented and should be repaired in the local workshops. The E10 and the S6 Power GSM are both handsets for GSM-900. Internally they are almost identical but the form factors of the boards are different.
  • Page 4 2.4.1Description of procedure: 2.4.1.1Diagnosis Check the output frequency of the VCXO using the level-2 testing program for E10 / S6 Power GSM. Switch off the „CMD in Use“ option in the S611.INI file and restart V1.2 Page 4 of 22 ICP CD ST D.
  • Page 5 Information and Communication Communication Devices the program. Start the test, when the program says „Check power and phase of external antenna with your GSM-Tester“, switch the CMD to „LOCAL“ mode and enter the „MODULE TEST“. On the CMD display you can see the frequency error of the handset. (Make sure that the CMD is on channel 124, power level 5!) If the frequency error is higher than 2kHz, the VCXO has to be replaced.
  • Page 6 Information and Communication Communication Devices Soldering Iron 2.4.2.3Special Tools None 2.4.2.4Working materials Desolder Wick / Braid Solder V1.2 Page 6 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 7 Information and Communication Communication Devices 2.4.3Drawings Figure 1: E10 / S6 Power GSM Board VCXO Side V1.2 Page 7 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 8: 3Fuse 1A

    Information and Communication Communication Devices Figure 2: VCXO (Z601) Placement (Top View) 3Fuse 1A 3.1Affected Units 3.1.1Type: E10 / S6 Power GSM 3.1.2Affected IMEIs / Date Codes: All / All 3.1.3Affected SW-Versions: 3.1.4Fault Code for LSO reporting: 3FU1 3.2Fault Description 3.2.1Fault Symptoms for customers:...
  • Page 9 Information and Communication Communication Devices 3.2.2Fault Symptom on GSM-Tester: This fault cannot be detected with a GSM-Tester 3.3Priority:  ..Mandatory  ..Repair  ..Optional  ..Not Yet Defined 3.4Repair Documentation 3.4.1Description of procedure: 3.4.1.1Diagnosis Check the status of the fuse by measuring its resistance with a multimeter.
  • Page 10 Information and Communication Communication Devices 3.4.1.4Test Retest handset after repair as described above. The resistance must now be close to zero. 3.4.2List of needed material 3.4.2.1Components Fuse Part-Number: L36145-A820-Y7 3.4.2.2Jigs and Tools Soldering Iron 3.4.2.3Special Tools Multimeter 3.4.2.4Working materials Desolder Wick / Braid Solder V1.2 Page 10 of 22...
  • Page 11 Information and Communication Communication Devices 3.4.3Drawings Figure 1: E10 / S6 Power GSM Board 1A Fuse Side Figure 2: 1A Fuse (F201) Placement (Top View) V1.2 Page 11 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 12: 4Fuse 0.25 A

    Information and Communication Communication Devices 4Fuse 0.25 A 4.1Affected Units V1.2 Page 12 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 13 Information and Communication Communication Devices 4.1.1Type: E10 / S6 Power GSM 4.1.2Affected IMEIs / Date Codes: All / All 4.1.3Affected SW-Versions: 4.1.4Fault Code for LSO reporting: 3FU2 4.2Fault Description 4.2.1Fault Symptoms for customers: Supplying of external accessories through the handset’s bottom connector is not possible 4.2.2Fault Symptom on GSM-Tester:...
  • Page 14 Information and Communication Communication Devices a multimeter. The fuse is defective if the resistance higher than 10 ohms 4.4.1.2Repair by component change Use soldering iron to remove defective fuse. Avoid excessive heat! Watch surrounding components! Resolder new fuse afterwards. 4.4.1.3Repair by SW-Booting Not possible! 4.4.1.4Test Retest handset after repair as described above.
  • Page 15 Information and Communication Communication Devices Figure 1: E10 / S6 Power GSM 0.25A Fuse Side Figure 2: E10 / S6 Power GSM 0.25A Fuse Placement V1.2 Page 15 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 16: 5Molex Connector

    Information and Communication Communication Devices 5Molex Connector 5.1Affected Units 5.1.1Type: E10 / S6 Power GSM 5.1.2Affected IMEIs / Date Codes: All / All 5.1.3Affected SW-Versions: 5.1.4 Fault Code for LSO reporting: 3MOC 5.2Fault Description V1.2 Page 16 of 22 ICP CD ST D.
  • Page 17 Information and Communication Communication Devices 5.2.1Fault Symptoms for customers: Network search. Charging or operation in a car kit not possible. 5.2.2Fault Symptom on GSM-Tester: Output power problems on the external and internal antenna. No location update possible. 5.3Priority:  ..Mandatory ...
  • Page 18 Information and Communication Communication Devices 5.4.1.4Test Retest handset after repair. 5.4.2List of needed material 5.4.2.1Components Molex Connector Part-Number: L36851-Z1351-A70 5.4.2.2Jigs and Tools Hot Air Blower Soldering Iron 5.4.2.3Special Tools None 5.4.2.4Working materials Desolder Wick / Braid Solder Flux V1.2 Page 18 of 22 ICP CD ST D.
  • Page 19 Information and Communication Communication Devices 5.4.3Drawings Figure 1: E10 / S6 Power GSM Board Bottom Connector Side Figure 2: Bottom Connector Placement (Top View) V1.2 Page 19 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 20: 6Ringer

    Information and Communication Communication Devices 6Ringer 6.1Affected Units 6.1.1Type: E10 / S6 Classic MMI 6.1.2Affected IMEIs / Date Codes: All / All 6.1.3Affected SW-Versions: 6.1.4Fault Code for LSO reporting: 3RIN 6.2Fault Description 6.2.1Fault Symptoms for customers: No ringer tone audible or ringer tone distorted.
  • Page 21 Information and Communication Communication Devices  ..Mandatory  ..Repair  ..Optional  ..Not Yet Defined 6.4Repair Documentation 6.4.1Description of procedure: 6.4.1.1Diagnosis Check ringer functionality either manually or with testing program. 6.4.1.2Repair by component change Use hot air blower remove defective ringer. Avoid excessive heat! Watch surrounding components, especially the display window! To protect the display, you can also desolder the ringer with solder...
  • Page 22 Information and Communication Communication Devices 6.4.2List of needed material 6.4.2.1Components Ringer Part-Number: a) E10: L36178-Z2-C14 b) S6 Power GSM: L36178-Z2-C16 6.4.2.2Jigs and Tools Hot Air Blower Soldering Iron 6.4.2.3Special Tools None 6.4.2.4Working materials Desolder Wick / Braid Solder V1.2 Page 22 of 22 ICP CD ST D.
  • Page 23 Information and Communication Communication Devices E10 / S6 Power GSM /S8 GSM Level 2.5 Repair Documentation V 1.2 V1.2 Page 1 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 24 Information and Communication Communication Devices Table of Contents: 1INTRODUCTION..............................2 2VCXO ....................................3 3FUSE 1A ....................................8 4FUSE 0.25 A ....................................12 5MOLEX CONNECTOR ....................................16 6RINGER ....................................20 1Introduction V1.2 Page 2 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 25 Failure highlights are documented and should be repaired in the local workshops. The E10 and the S6 Power GSM are both handsets for GSM-900. Internally they are almost identical but the form factors of the boards are different.
  • Page 26 2.4.1Description of procedure: 2.4.1.1Diagnosis Check the output frequency of the VCXO using the level-2 testing program for E10 / S6 Power GSM. Switch off the „CMD in Use“ option in the S611.INI file and restart V1.2 Page 4 of 22 ICP CD ST D.
  • Page 27 Information and Communication Communication Devices the program. Start the test, when the program says „Check power and phase of external antenna with your GSM-Tester“, switch the CMD to „LOCAL“ mode and enter the „MODULE TEST“. On the CMD display you can see the frequency error of the handset. (Make sure that the CMD is on channel 124, power level 5!) If the frequency error is higher than 2kHz, the VCXO has to be replaced.
  • Page 28 Information and Communication Communication Devices Soldering Iron 2.4.2.3Special Tools None 2.4.2.4Working materials Desolder Wick / Braid Solder V1.2 Page 6 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 29 Information and Communication Communication Devices 2.4.3Drawings Figure 1: E10 / S6 Power GSM Board VCXO Side V1.2 Page 7 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 30 Information and Communication Communication Devices Figure 2: VCXO (Z601) Placement (Top View) 3Fuse 1A 3.1Affected Units 3.1.1Type: E10 / S6 Power GSM 3.1.2Affected IMEIs / Date Codes: All / All 3.1.3Affected SW-Versions: 3.1.4Fault Code for LSO reporting: 3FU1 3.2Fault Description 3.2.1Fault Symptoms for customers:...
  • Page 31 Information and Communication Communication Devices 3.2.2Fault Symptom on GSM-Tester: This fault cannot be detected with a GSM-Tester 3.3Priority:  ..Mandatory  ..Repair  ..Optional  ..Not Yet Defined 3.4Repair Documentation 3.4.1Description of procedure: 3.4.1.1Diagnosis Check the status of the fuse by measuring its resistance with a multimeter.
  • Page 32 Information and Communication Communication Devices 3.4.1.4Test Retest handset after repair as described above. The resistance must now be close to zero. 3.4.2List of needed material 3.4.2.1Components Fuse Part-Number: L36145-A820-Y7 3.4.2.2Jigs and Tools Soldering Iron 3.4.2.3Special Tools Multimeter 3.4.2.4Working materials Desolder Wick / Braid Solder V1.2 Page 10 of 22...
  • Page 33 Information and Communication Communication Devices 3.4.3Drawings Figure 1: E10 / S6 Power GSM Board 1A Fuse Side Figure 2: 1A Fuse (F201) Placement (Top View) V1.2 Page 11 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 34 Information and Communication Communication Devices 4Fuse 0.25 A 4.1Affected Units V1.2 Page 12 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 35 Information and Communication Communication Devices 4.1.1Type: E10 / S6 Power GSM 4.1.2Affected IMEIs / Date Codes: All / All 4.1.3Affected SW-Versions: 4.1.4Fault Code for LSO reporting: 3FU2 4.2Fault Description 4.2.1Fault Symptoms for customers: Supplying of external accessories through the handset’s bottom connector is not possible 4.2.2Fault Symptom on GSM-Tester:...
  • Page 36 Information and Communication Communication Devices a multimeter. The fuse is defective if the resistance higher than 10 ohms 4.4.1.2Repair by component change Use soldering iron to remove defective fuse. Avoid excessive heat! Watch surrounding components! Resolder new fuse afterwards. 4.4.1.3Repair by SW-Booting Not possible! 4.4.1.4Test Retest handset after repair as described above.
  • Page 37 Information and Communication Communication Devices Figure 1: E10 / S6 Power GSM 0.25A Fuse Side Figure 2: E10 / S6 Power GSM 0.25A Fuse Placement V1.2 Page 15 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 38 Information and Communication Communication Devices 5Molex Connector 5.1Affected Units 5.1.1Type: E10 / S6 Power GSM 5.1.2Affected IMEIs / Date Codes: All / All 5.1.3Affected SW-Versions: 5.1.4 Fault Code for LSO reporting: 3MOC 5.2Fault Description V1.2 Page 16 of 22 ICP CD ST D.
  • Page 39 Information and Communication Communication Devices 5.2.1Fault Symptoms for customers: Network search. Charging or operation in a car kit not possible. 5.2.2Fault Symptom on GSM-Tester: Output power problems on the external and internal antenna. No location update possible. 5.3Priority:  ..Mandatory ...
  • Page 40 Information and Communication Communication Devices 5.4.1.4Test Retest handset after repair. 5.4.2List of needed material 5.4.2.1Components Molex Connector Part-Number: L36851-Z1351-A70 5.4.2.2Jigs and Tools Hot Air Blower Soldering Iron 5.4.2.3Special Tools None 5.4.2.4Working materials Desolder Wick / Braid Solder Flux V1.2 Page 18 of 22 ICP CD ST D.
  • Page 41 Information and Communication Communication Devices 5.4.3Drawings Figure 1: E10 / S6 Power GSM Board Bottom Connector Side Figure 2: Bottom Connector Placement (Top View) V1.2 Page 19 of 22 ICP CD ST D. Schnoor 06/98...
  • Page 42 Information and Communication Communication Devices 6Ringer 6.1Affected Units 6.1.1Type: E10 / S6 Classic MMI 6.1.2Affected IMEIs / Date Codes: All / All 6.1.3Affected SW-Versions: 6.1.4Fault Code for LSO reporting: 3RIN 6.2Fault Description 6.2.1Fault Symptoms for customers: No ringer tone audible or ringer tone distorted.
  • Page 43 Information and Communication Communication Devices  ..Mandatory  ..Repair  ..Optional  ..Not Yet Defined 6.4Repair Documentation 6.4.1Description of procedure: 6.4.1.1Diagnosis Check ringer functionality either manually or with testing program. 6.4.1.2Repair by component change Use hot air blower remove defective ringer. Avoid excessive heat! Watch surrounding components, especially the display window! To protect the display, you can also desolder the ringer with solder...
  • Page 44 Information and Communication Communication Devices 6.4.2List of needed material 6.4.2.1Components Ringer Part-Number: a) E10: L36178-Z2-C14 b) S6 Power GSM: L36178-Z2-C16 6.4.2.2Jigs and Tools Hot Air Blower Soldering Iron 6.4.2.3Special Tools None 6.4.2.4Working materials Desolder Wick / Braid Solder V1.2 Page 22 of 22 ICP CD ST D.

This manual is also suitable for:

S6S8