e. Spin Drying
Spin drying cycle
does not work.
Note:
1.
The tub switch works 3 times
continuously or works 1 time in the
single program of spin-d
number window LED display abnormal
code:
and begin blinking on and
off at the same time and the electric
buzzer sounds to indicate a problem.
2. Do not disconnect the wire from the
capacitor, because
de-pressing noise from outside to the
micro-computer.
TROUBLE
Operation of safety device
Start of spin-drying.
Yes
Machine inclines.
Does safety
device work?
No
The V-belt is slipping.
The V-belt is snapped.
Small pulley mounting
ry
. The
screw is loosed.
Motor is disconnected or
burnt.
Capacitor is broken or
disconnected.
this wire acts as
Bearing ass
Torque motor is defective.
Brake lever is defective.
Thermostat on motor is
opened.
Poor contact of 6-pin
connectors (blue &white).
Control circuit board is
defective.
INSPECTION
INSPECTION
INSPECTION
Safety device work.
Electric circuit
count operation of
safety device.
'
y is defective.
CAUSES
Normal spin.
Electric circuit works to stop
spin when safety device
detects continuously three
times of abnormal swing of
spin drum.
7
Replace with level.
Adjust the motor
position.
Replace.
Tighten up.
Replace.
Replace.
Replace.
Replace.
Repair or replace.
Repair or replace
after cooling down.
Repair or replace.
Replace.
X
REMEDY