Page 1
SERVICE MANUAL Automatic Washer XQB100-Y1066S SPECIFICATION Power source AC 230-240V, 50Hz Overall dimension 601(W) × 626(D) × 985(H) Net weight 47kg Power consumption 450W Motor output 250W Washing method Automatic reverse turn Water capacity 90 Liters Spinner tub speed 680 r.p.m Specification: Subject to change without notice.
6) Abnormal condition of load sensor. The number window LED display abnormal code: and begin blinking on and off at the same time and the electric buzzer sounds to indicate a problem. XQB100-Y1066S CIRCUIT DIAGRAM...
COLOR SYMBOL GRAY BLUE GREEN BLACK LIGHT BLUE BROWN ORANGE PINK WHITE YELLOW VIOLET TROUBLE SHOOTING TROUBLE INSPECTION INSPECTION CAUSES REMEDY a. Power Source Any indications Is fuse blown? Deterioration of fuse. Replace. and beep do not Motor is defective. Replace.
Page 4
b. Water Supply Water does not Does humming Something on the filter of flow when the noise come on the water valve or hose Clean the filter. power switch is from water joint assembly. start Valve? button is pressed. Poor connect of 6-pin Repair or replace.
Page 5
Replace or Something on the disassemble the diaphragm on the water valve and clean valve. the diaphragm Diaphragm is deformed Replace Replace . XQB100-Y1066S Replace TROUBLE CAUSES REMEDY INSPECTION c.Wash/Rinse ’ Bearing ass y is defective. Replace. Washing cycle does...
Page 6
Water does not hose. inside. drain out. Pump lead wire Repair or replace. disconnected. Control circuit board is Replace. defective. XQB100-Y1066S TROUBLE INSPECTION INSPECTION INSPECTION CAUSES REMEDY ’ Drain takes time Drain hose ass y is deformed. Replace or replace.
e. Spin Drying Spin drying cycle Machine inclines. Replace with level. Does safety does not work. device work? The V-belt is slipping. Adjust the motor position. Note: The V-belt is snapped. Replace. The tub switch works 3 times Small pulley mounting Tighten up.
Page 8
Something in water valve. Replace. INSPECTION INSPECTION during water pressure (more supply. than 4kg/cm High Adjust faucet Faucet open too far turning. XQB100-Y1066S TROUBLE INSPECTION INSPECTION CAUSES REMEDY Buzzing/rattling Does some noise Belt is slipping. Adjust. during washing sound during Pulley is loose.