2 Installation and Connections
Wiring for ON/OFF Illumination (NPN Only)
Warning: Contact between Pin 5 (gray wire) and any voltage source greater than 3.5 VDC will damage the Illuminator.
Smart Series Illuminator
Connector
Smart Series Illuminator
Pin
Signal Name
1
+24VDC
2
Trigger –
3
DC Ground
4
Trigger +
5
Dim
Insulate Pin 5 (Gray Wire)
Wiring for Continuous Illumination
Warning: Contact between Pin 5 (gray wire) and any ground or voltage source less than or equal to 3.5VDC may
cause erratic operation in this configuration. Contact between Pin 5 (gray wire) and any voltage source greater
than 3.5VDC will damage the illuminator.
Smart Series Illuminator
Connector
Smart Series Illuminator
Pin
Signal Name
1
+24VDC
2
Trigger –
3
DC Ground
4
Trigger +
5
Dim
Insulate Pin 5 (Gray Wire)
2-16
F440-F Connector A
(Connector A)
to
Pin
to
to
7 and 12
Ground and Output Common
to
7 and 12
Ground and Output Common
to
2
6
F440-F Connector A
(Connector A)
to
Pin
Signal Name
to
2
to
7
to
7
to
2
No Connection*
Signal Name
Power
Power
Output 3
Power
Ground
Ground
Power
N/A