LG GWL6026SC Service Manual page 9

Table of Contents

Advertisement

Heavy Repair Method of Refrigerator by Application of Refrigerant
2-6. Refrigerant Charging
Required equipment: Bombe, R600a refrigerant (80g)
Firstly remove fire appliances and heating source for performing work when charging scaled refrigerant. (Do not spray refrigerant
indoor.)
Measure the accurate quantity (80g) of refrigerant to charge it into a Bombe.
Make the Bomber as vacuum status to charge refrigerant.
(If there is air or moisture in a Bombe, it may give effect on performance of a cooling cycle.)
Please manage refrigerant quantity as 80g±1. Differently from R134a, R600a gives much effect on
cooling performance depending on change of refrigerant quantity.
Refrigerant quantity = Weight after charging – Weight before charging (weight of vacuumed Bombe)
Connect Bombe with a charging tube to charge refrigerant.
Turn on power of refrigerator to operate a compressor.
Measure Bombe weight after 5 through 10 minutes to check remained refrigerant quantity to complete charging of refrigerant.
(After charging refrigerant, never perform welding work or work using fire appliances.)
2-7. Leak Inspection and Cycle Check
Required equipment: Leakage checking machine (foam and leakage inspection machine)
Check for leakage by using form or a leakage inspection machine at the worked part if charging of refrigerant is completed.
Check for leakage at the low pressure part with the compressor stopped, and check at the high pressure part with the compressor
being operating.
If leakage is detected, proceed to repair according to repair process again starting from "2-1. Returnof Refrigerator Refrigerant".
(Never perform welding work or work using fire appliances.)
Check that heat remains at a discharge pipe or condenser with the hands if leakage check is completed. If heat remains, the
cooling cycle is normal.
(Take care since a discharge pipe may be hot.)