TROUBLE DIAGNOSIS

1-3.
Other troubleshooting
Crush Mode doesn't work
Is the connection loose ?(CON3)
No
2
CON3
7
8
Main PCB
19
CON7
20
Yes
Reconnect
BL
Auger Motor
WH
M
GY
Lever S/W
WH
YL
In Crush Mode,
Is the voltage between
pin2 and pin7
of CON3 like as below,
while pushing the lever
switch?
Pin7
Auger Motor (CCW) VOLTAGE
LEVER
S/W
Push
Normal
SVC Manual
Wiring diagram
No
Pin2
Test Point
Result
pin7 To pin2
220~240 V
pin7 To pin2
Yes
Replace
MAIN PCB
0 ~ 2V