Replacing The Operating Diaphragm - Samson 44-7 Mounting And Operating Instructions

Excess pressure valve
Table of Contents

Advertisement

Assembly of Type 44-7
1. Screw in the seat using a seat wrench.
Observe the tightening torques specified
in section 8.4.
2. Renew the seal (1.3) and insert it into the
body.
3. DN 15 to 25: insert and screw in the
guide nipple (3.6). Observe the tighten-
ing torques specified in section 8.4.
DN 32 to 50: insert the the guide nipple
(3.6) and screw in the plug nipple (3.5).
Observe the tightening torques specified
in section 8.4.
4. Place the plug (3) onto the plug stem and
screw on the plug nut (3.2). Observe the
tightening torques specified in sec-
tion 8.4.
5. Renew the seal (1.2) and insert it into the
body.
6. Screw in the body stopper (1.1). Ob-
serve the tightening torques specified in
section 8.4.
7. Check the facings of the actuator hous-
ing (6) for dirt and clean them, if neces-
sary.
8. Place the actuator housing (6) on the
valve body (1) and screw tight the body
screws (13). Observe the tightening
torques specified in section 8.4.
9. Screw on the control line (11). Observe
the tightening torques specified in sec-
tion 8.4.
10. Put the regulator into operation (see sec-
tion 5.3).
EB 2723 EN
8.2 Replacing the operating
diaphragm
DANGER
!
Risk of personal injury due to preloaded
springs.
Regulators in combination with preloaded
set point springs are under tension. These
regulators can be identified by the red warn-
ing label on the actuator's set point springs.
− Before starting any work on the springs,
relieve the compression from the preloaded
springs.
− Only use the SAMSON disassembly tool
(1280-4052).
NOTICE
!
Risk of regulator damage due to exces-
sively high or low tightening torques.
Observe the specified torques when tighten-
ing regulator components. Excessive tighten-
ing torques lead to parts wearing out more
quickly. Parts that are too loose may cause
leakage.
Observe the specified tightening torques.
NOTICE
!
Risk of TÜV approval (based on AGFW
worksheet FW 506) for Type 44-4 becom-
ing void.
Consult SAMSON's After-sales Service be-
fore you change parts or perform service or
repair work on TÜV-tested Type 44-4 Regu-
lators.
Servicing
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

44-4

Table of Contents