Carrier 59SC6A Installation Instructions Manual page 65

Single-stage, high efficiency, 4-way multipoise 35-in. (889 mm), condensing gas furnace
Table of Contents

Advertisement

59SC6A: Installation, Start-up, Operating and Service and Maintenance Instructions
b. Connect vent connector to vent elbow.
17. Turn on electrical supply. Manually close blower door switch.
Check for proper rotation. If outdoor temperature is below 70_F
(21_C), turn off circuit breaker to outdoor unit before running
furnace in the cooling cycle. Turn outdoor circuit breaker on after
completing cooling cycle. See
NOTE: If R-W/W1 thermostat terminals are jumpered at the time
blower door switch is closed, blower will run for 90 sec before
beginning a heating cycle.
BLOWER WHEEL SET-SCREW
SHALL BE TIGHTENED TO
160 IN.-LB. +/-20 IN. -LB.
MOTOR SHAFT FLAT
BRACKET
BLO HSG ASSY
SCREW
LOCATIONS
ENSURE THAT
WRAPPER IS OVER
TAB ON EACH SIDE
BRACKET, BLO MTG (LEFT)
SCREW (3)
SCREW (2)
BRACKET, BLO MTG (RIGHT)
SCREW (3)
Fig. 67 – Blower Assembly on
100M21
a. Perform component self-test as shown at the bottom of the
SERVICE label, located on the control door.
b. Verify blower is rotating in the correct direction
18. If furnace is operating properly, RELEASE BLOWER DOOR
SWITCH. Remove any jumpers or reconnect any disconnected
thermostat leads. Replace blower door.
19. Turn on gas supply and cycle furnace through one complete heating
cycle. Verify the furnace temperature rise as shown in Adjustments
Section. Adjust temperature rise as shown in Adjustments Section.
Cleaning Burners and Flame Sensor
The following items must be performed by a qualified service
technician. If the burners develop an accumulation of light dirt or dust,
they may be cleaned by using the following procedure:
NOTE: Use a back-up wrench on the gas valve to prevent the valve
from rotating on the manifold or damaging the mounting to the burner
assembly.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Fig.
38.
GROMMET
MOTOR
COLLAR
ARM
WASHER
BLOWER
WHEEL
HUB
BLO HSG ASSY
SCREW
BLOWER MOTOR
SCREW
22
--
ELECTRICAL SHOCK AND FIRE HAZARD
Failure to follow this warning could result in personal injury, death,
and/or property damage.
Turn off the gas and electrical supplies to the furnace and install lockout
tag before performing any maintenance or service. Follow the operating
instructions on the label attached to the furnace.
Refer to
Fig.
68.
1. Disconnect power at external disconnect, fuse or circuit breaker.
2. Turn off gas at external shut-off or gas meter.
SCREW
3. Remove control door and set aside.
4. Turn electric switch on gas valve to OFF.
5. Disconnect the gas pipe from gas valve and remove pipe from the
furnace casing.
6. Remove individual wires from terminals on gas valve.
7. Disconnect Hot Surface Igniter (HSI) wires from HSI.
8. Disconnect Flame Sensor wire from Flame Sensor.
9. Support the manifold and remove the 4 screws that secure the
manifold assembly to the burner assembly and set aside. Note the
location of the green/yellow wire and ground terminal.
10. Inspect the orifices in the manifold assembly for blockages or
obstructions. Remove orifice and clean or replace orifice.
11. Remove the four screws that attach the top plate of the casing to the
furnace.
12. Raise top plate up slightly and prop it up with a small piece of wood
or folded cardboard.
13. Support the burner assembly and remove the screws that attach the
burner assembly to the heat exchanger cell panel.
14. Remove wires from both rollout switches.
15. Slide one--piece burner out of slots on sides of burner assembly.
16. Remove the flame sensor from the burner assembly.
17. (Optional) Remove the Hot Surface Igniter (HSI) and bracket from
the burner assembly.
18. Check igniter resistance. Nominal resistance is 40 to 70 ohms at
room temperature and is stable over the life of the igniter.
19. Clean burner with a brush and a vacuum.
20. Clean the flame sensor with fine steel wool (0000 grade). Do not
use sand paper or emery cloth.
A190407
BURNER SUPT. ASSY
BURNER ASSY
To reinstall burner assembly:
1. Install the Hot Surface Igniter (HSI) and bracket in burner
assembly.
2. Install flame sensor on burner.
65
WARNING
!
IGNITER
BRACKET, IGNITER
FLAME SENSOR
(BELOW BURNER)
Fig. 68 – Burner Assembly
FLAME ROLLOUT
SWITCH
A11403

Hide quick links:

Advertisement

Table of Contents
loading