20 INSTALLATION
Flexible Connector Hookup
Pressure
regulator
/
" Adapter
1
2
Flex connector
(6 ft. max.)
Installer: Inform the consumer of the location of the gas
.
shutoff valve
Pressure Regulator Position
Pressure Regulator

Connecting Electricity

Electrical Requirements
If an external electrical source is utilized, the appliance,
when installed, must be electrically grounded in
accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electric Code, CSA C22.1-02.
All wiring should conform to Local and NEC codes.
This range requires a single-phase, 3 wire, A.C
120/208 V or 120/240 V 60 Hz electrical system. Use
only a 3-conductor or a 4-conductor UL - listed range
cord with closed-loop terminals, open-end spade
lugs with upturned ends or similar termination. Do not
install the power cord without a strain relief.
A range cord rated at 40 amps with 120/208 or 120/240
minimum volt range is required. If a 50 amp range
cord is used, it should be marked for use with 1
diameter connection openings. This appliance may
be connected by means of a conduit or power cord.
If a conduit is being used, go to page 22 for 3 wire
conduit connections or 4 wire conduit connections.
1
/
" Adapter
2
Gas shut-off valve
1
/
" Adapter
1
/
" or
3
/
"
2
2
4
Gas pipe
/
"
3
8
WARNING
• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack
in the line so that the range can be moved if
servicing is ever necessary.
• The power supply cord and plug should
not be modified. If it will not fit the outlet,
have a proper outlet Installed by a qualified
electrician.
• Using an extension cord to connect the
power is prohibited. Connect the power cord
and plug directly.
• Electrical ground is required on this appliance.
• Make sure that the power cord is not pinched
by the range or heavy objects. Failure to do so
can result in serious burns or electrical shock.
• Do not use a damaged power plug, power
cord, or loose power outlet.
• Do not put a fuse in a neutral or ground circuit.
• Do not connect the ground wire to plastic
plumbing lines, gas lines, or hot water pipes.
Specified power-supply-cord kit rating
Range rating, watts
120/240
120/208
volts
volts
3-wire
3-wire
8,750 -
7,801 -
16,500
12,500
16,501 -
12,501 -
22,500
18,500
3, 4 - Wire electrical wall Receptacle
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)
Connecting the Power Cord
The rear access cover must be removed. Loosen the
two screws with a screwdriver. The terminal block will
then be accessible.
Access cover
Diameter (inches)
Specified
of Range
rating of
connection
power
Opening
supply-
cord kit,
Power
Conduit
amperes
cord
40 or 50A
1
/
"
3
8
50
1
/
"
3
4
1
/
"
1
8
1
/
"
3
8

Advertisement