Current Consumption; Residual Battery Display - Canon EOS 40D Service Manual

Hide thumbs Also See for EOS 40D:
Table of Contents

Advertisement

1.2 Current Consumption
Current Consumption Standards
Lens: EF 50mm f/1.8 II
Power source: Constant voltage 8.0 V, 0.40Ω. (No CF card installed)
Ambient conditions: Room temperature, normal humidity (below 60%)
Camera Status 
Main SW off
SW1-ON
Self Timer operation
Red-eye Lamp operation
AF Search operation
Standby
Self-Cleaning Function ON
*  T he "Actual Measurement" data was based on rough measurement. Therefore, be sure to refer to average data of 
multiple cameras at each repair site.
*Standby means the condition where the camera is inactive, but the Main SW is on.
Constant-Voltage 
Power Source
+
-
1.3 Residual Battery Display
Tool: Use the tool battery and resistance part.
Power: Set the power supply to 8.0V.
⑴Insert the tool battery into the camera.
⑵Turn on the main SW.
⑶  R aise supply voltage gradually and release the camera within each 
voltage range to check if the display switches from one to another.
All manuals and user guides at all-guides.com
Standard 
100 A or lower
350mA or lower
550mA or lower
600mA or lower
500mA or lower
100mA or lower
650mA or lower
Digital tester or 
other ammeter
+
-
Fig. 006
3
Repair Information
Actual Measurement
45.52 A
116.46mA
155.33mA
179.6mA
274.4mA
39.8mA
420.4mA
Tools battery
To camera
Fig. 007
7.8±0.1 V
7.5±0.1 V
7.1±0.1 V

Advertisement

Table of Contents
loading

This manual is also suitable for:

C12-6171

Table of Contents