1. Press the forward (J) or back (H) arrow to highlight the field to
change.
2. Press the select button (I) to activate the field. The field will turn
green.
3. Press the forward (J) or back (H) arrow to change the activated
field.
4. Press the select button (I) to save the changes.
5. Repeat the steps above to change the remaining fields.
6. Press the menu/power button (L) to exit.

BASIC OPERATION

Main Viewing Screen
The main screen includes several sections:
Q. Scanned area image
R. Temperature measurement at center of image (+)
S. Emissivity setting
T. Battery fuel gauge
U. Temperature color scale
R
Q
Image Blend
The DCT416 Imaging Thermometer has the ability to display both a
visual image and an infrared image. The images can also be blended
on the display to provide an overlay of the thermal image on top of the
visual image. A blended image can be helpful in diagnosing trouble
spots or communicating with customers.
To change the blend setting, push the image blend adjust button
(K). The image blend can be pushed repeatedly to cycle through the
following options for display settings:
100% Visual
75% Visual, 25% Thermal
50% Visual, 50% Thermal
25% Visual, 75% Thermal
100% Thermal
Take and Store Photos
Make sure a micro SD card is installed in order to save a photo. Open
micro SD card slot cover (D) and insert the micro SD card into the
slot (E).
10
T
S
U