Cordless imaging thermometer
Hide thumbs Also See for XR LI-ION DCT416:

Advertisement

DCT416
www.
.eu

Advertisement

Table of Contents
loading

Summary of Contents for DeWalt XR LI-ION DCT416

  • Page 1 DCT416 www.
  • Page 2 Figure 1 Figure 2 f, g d, e Figure 3 Figure 4...
  • Page 3: Technical Data

    EN GL IS H CORDLESS IMAGING THERMOMETER DCT416 Congratulations! Charger DCB100 DCB105 You have chosen a D WALT tool. Years of Mains voltage V experience, thorough product development and Battery type Li-Ion Li-Ion innovation make D WALT one of the most reliable Approx.
  • Page 4: Important Safety Instructions

    EN GLI SH imaging thermometer may be dangerous in Denotes risk of electric shock. the hands of untrained users. Use the imaging thermometer, accessories, etc. in accordance with Denotes risk of fire. these instructions, taking into account the working conditions and the work WARNING: To reduce the risk of injury, to be performed.
  • Page 5: Residual Risks

    EN GL IS H • Do not use imaging thermometer for operate the imaging thermometer testing temperatures of cooked or within the operating range noted in the uncooked food. specification chart. • Do not touch surfaces to confirm hot NOTICE: Do not point the imaging temperature readings.
  • Page 6: Important Safety Instructions For All Battery Chargers

    EN GLI SH Important Safety Instructions for All • Do not place any object on top of charger or place the charger on a soft surface that Battery Chargers might block the ventilation slots and result in excessive internal heat. Place the charger SAVE THESE INSTRUCTIONS: This manual in a position away from any heat source.
  • Page 7: Charging Process

    EN GL IS H • Do not store or use the tool and battery NOTE: To ensure maximum performance and life of pack in locations where the temperature Li-Ion batteries, charge the battery pack fully before may reach or exceed 40 ˚C (105 ˚F) (such as first use.
  • Page 8: Storage Recommendations

    EN GLI SH Storage Recommendations Do not incinerate the battery pack. 1. The best storage place is one that is cool and dry, away from direct sunlight and excess heat or cold. For optimum battery performance and See Technical data for charging time. life, store battery packs at room temperature when not in use.
  • Page 9: Electrical Safety

    EN GL IS H Using an Extension Cable Menu/Power Button: Press this button to power the unit on An extension cord should not be used unless (hold for 0.5 seconds) or off (hold absolutely necessary. Use an approved extension for 3 seconds). When the unit is cable suitable for the power input of your charger powered on, press this button to view (see Technical Data).
  • Page 10 EN GLI SH TO INSTALL THE BATTERY PACK INTO THE TOOL HANDLE BASIC OPERATION 1. Align the battery pack (a) with the rails inside the Main Viewing Screen handle. The main screen includes several sections: 2. Slide it firmly into place until you hear the lock r.
  • Page 11 EN GL IS H 4. Press the select button (i) to confirm selection. 3. Press the select button (i) to confirm selection. 5. After completion of save or delete, the imaging 4. Press the forward (j) or back (h) arrow to scroll thermometer will automatically return to the through saved images.
  • Page 12 EN GLI SH measurement of a target with a shiny or metallic Water 0.67 surface. Experimentation may be required to Black Loam 0.66 benchmark temperatures, and experience will Cement, white 0.65 help you choose the best setting for specific Iron cast, oxidized 0.64 measurements.
  • Page 13 EN GL IS H 3. Press the select button (i) to confirm selection. Background Temperature 4. Press the forward (j) or back (h) arrow to scroll For more accurate temperature measurements, it is through the color palette options. The five recommended to set the background (or reflected palette choices include: Ironbow, White Hot, temperature).
  • Page 14 EN GLI SH 3. Press the select button (i) to confirm selection 4. The imaging thermometer will display the software version. 5. Press the menu/power button (l) to exit. To Change Temperature Scales 1. Press the menu/power button (l). 2. Press the forward (j) or back (h) arrow to highlight the C / F option in the menu.
  • Page 15: Maintenance

    The imaging thermometer utilises report writing not clean the infrared lens too vigorously software to produce professional reports. The as this can damage the delicate anti- software can be downloaded from www.dewalt.eu reflective coating. or www.2helpU.com. CHARGER CLEANING INSTRUCTIONS To Turn Off Imaging Thermometer WARNING: Shock hazard.
  • Page 16: Rechargeable Battery Pack

    EN GLI SH Should you find one day that your D WALT product GUARANTEE needs replacement, or if it is of no further use to you, do not dispose of it with household waste. Make this WALT is confident of the quality of its product available for separate collection.