Cycles Per Minute (CPM) Rate

The pump cycle rate is adjustable to accommodate different pump sizes, varying product viscosities and product
delivery speed. The pump cycle rate is measured in Cycles Per Minute (CPM), i.e. the number of times the pump
performs a pump cycle in one minute. One pump cycle consists of a momentary pressurization of each one of the
two diaphragms.

Adjustment

The CycleFlo II comes with a cycle rate adjustment relay
that can be adjusted using a screwdriver to control the
energizing and deenergizing rate of the built-in solenoid
valves. This timer is adjustable between 10 and 200 cpm.
Turning the screw clockwise will decrease the cycle rate
of the pump. Turning the screw counter-clockwise will
increase the cycle rate of the pump.
8
309004
Setup & Adjustment
Electric Shock Hazard
To prevent accidental shock or
electrocution disconnect the supply
signal before opening the enclosure
cover.
Cycle rate adjustment