Spraying Techniques; Maintenance - Graco 980 Instructions Manual

Non-bleeder style turbine spray guns
Hide thumbs Also See for 980:
Table of Contents

Advertisement

General Spraying Techniques
D Select proper fluid set. To determine correct fluid
set see charts on page 10.
D When fluid is first applied, start with fluid nozzle and
air cap adjusted to "normal spray pattern" position.
Then adjust as needed. See Fig. 10 for pattern size
adjustment.
D Keep gun perpendicular to surface and maintain
consistent distance of approximately 6 to 8 inches
(150 to 200 mm) from object being sprayed.
See Fig. 13.
D Always have spray gun in motion before triggering.
Move spray gun across workpiece in straight,
smooth, stroke. Maintaining speed and distance.
Release trigger at end of stroke.
D To obtain even finish, overlap previous strokes
by 50%.
D Apply full, wet coat whenever possible.
Automotive Spraying Techniques
D When blending spots, work from outside in.
D Two 20-foot (6.1 m) hoses are recommended when
applying automotive finish coats. Additional hose
allows air to cool for better flow.
Turbine Filter Maintenance
Turbine systems are lifetime lubricated. The only
maintenance required is filter cleaning and
replacement.
Turbine main filter and pre-filter must be clean at all
times to provide sufficient air flow to cool motor and
atomize fluid. Check turbine pre-filter daily for
cleanliness. Check the main paper filter weekly,
minimum. Clean as necessary.
NOTE: To check filter, turn on turbine and place piece
of paper against pre-filter. If air intake holds paper in
place, filter is okay.

Spraying Techniques

Maintenance

6 to 8 in.
(150 to 200 mm)
Fig. 13
To clean main filter:
1. Turn off and unplug turbine.
2. Loosen four main filter screws, remove filter
retainer and pre-filter.
3. Remove main filter and clean by following one of
the following three methods:
D
Tap filter gently on flat surface, dirty side
down.
D
Direct maximum of 100 psi (0.7 MPa, 7 bar)
compressed air through filter panel in opposite
direction of arrows on side of filter.
D
Soak filter for 15 minutes in water and mild
detergent. Rinse filter until clean. Air dry filter;
do not use compressed air.
WARNING
To avoid damage to the turbine and possible electric
shock, never install a damp filter in the turbine.
0793
RIGHT
0793
WRONG
308810