Troubleshooting By Symptom (Base Unit And Charger Unit) - Panasonic KX-TG1061M Service Manual

Telephone equipment
Hide thumbs Also See for KX-TG1061M:
Table of Contents

Advertisement

9.2.

Troubleshooting by Symptom (Base Unit and Charger Unit)

If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on wether you have DECT tester
(*1) or not.
Note:
(*1) A general repair is possible even if you don't have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (Base Unit) (P.51)
9.2.1.
Check Point (Base Unit)
Please follow the items below when BBIC, EEPROM or FLASH is replaced.
Note:
After the measuring, suck up the solder of TP.
*: How to install Batch file into P.C. (P.66) is required beforehand.
The connections of simulator equipments are as shown in Adjustment Standard (Base Unit) (P.67).
Items
(A) 3.5 V Supply Confirma-
tion
(B) 3.75 V Supply Confirma-
tion
(C) 2.5 V Supply Confirma-
tion
(D) 3.0 V Supply Confirma-
tion
(E) 1.8 V Supply Confirma-
tion
(F)*
BBIC Confirmation
(G)* EEPROM Confirmation
(H)* BBIC Clock Adjustment
Check
Point
VDD3
1. Confirm that the voltage between test point VDD3 and GND is 3.5 V ± 0.2 V.
VDD5
1. Confirm that the voltage between test point VDD5 and GND is 3.75 V ± 0.2 V.
VDD2
1. Confirm that the voltage between test point VDD2 and GND is 2.5 V ± 0.2 V.
VDD4
1. Confirm that the voltage between test point VDD4 and GND is 3 V ± 0.2 V.
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.1 V.
-
1. BBIC Confirmation (Execute the command "getchk").
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
-
1. EEPROM Confirmation (Execute the command "sendchar EPV").
2. Confirm the returned value.
(Value for reference is written at"EEPROM C/SUM" in
Software_Version_Table.xls)
Note:
"checksum" vary depending on the country version. You can find them in the
batch file, PNZZ- mentioned in The Setting Method of JIG (Base Unit) (P.65).
CLK
1. Check X'tal Frequency. (10.368 MHz ± 100 Hz).
GND_C
Input Command "sendchar sfr", then you can confirm the current value.
2. If the frequency is not 10.368 MHz ± 100 Hz, Adjust the frequency of CLK exe-
cuting the command "sendchar sfr XX YY (where XX YY is the value)" so that
the reading of the frequency counter is 10.368000 MHz ± 20 Hz.
Procedure
51
KX-TG1061M/KX-TG1062M/KX-TGA106M
Check or
Replace Parts
IC301,R311,
R312,C311,
D301,F301
IC304,R384,
R385,C385,
D301,F301
D311,IC303
C504,R387,
IC501
Q351,IC501
IC501
IC561
IC501,X511

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tg1062mKx-tga106m

Table of Contents