TROUBLESHOOTING
NO
Error Code
Item
Comp Starting
8
Failure Error
9
Comp IPM Fault
Comp Abnormal
10
Current Detec-
tion Error
Comp Motor Re-
11
striction Error
Comp Low Volt-
12
age Error
Comp Overvolt-
13
age Error
Note. Some models may not include the C Fan.
Description
The error code is displayed
when the compressor has
failed to start.
The error code is displayed
when the compressor IPM
fault error has occurred.
The error code is displayed
when the compressor
location detection failed.
The error code is displayed
when the compressor motor
is constrained.
The error code is displayed
when the AC Input Voltage
is too low.
The error code is displayed
when the AC Input Voltage
is too high.
Trouble Shooting
Check the soldering status of the
inverter PCB. (Check if any parts
have short-circuited).
Check if the DC 16V output is less
than 1 3.5V.Check the Comp and
Cycle.
Check the compressor wire connec-
tions. Check the soldering status of
the inverter PCB. (Check if any parts
have short-circuited).
Check the Comp and Cycle.
Check if the compressor and the
Cycle is normal.
Check the input voltage.
Check the soldering of the invert-
er PCB. (Check if any parts have
short-circuited.)
Check Input voltage.
(This error occurs when the input
voltage is below voltage or lower.)
AC 53V (Input power AC 110~127V) or
AC 106V (Input power AC 220~240V)
Check Input voltage. (This error
occurs when the input voltage is
below voltage or higher.)
AC 155V(Input power AC 110~127V) or
AC 310V(Input power AC 220~240V)