Bradford White EF120T4003NA3 Service Manual page 23

Commercial ultra high efficiency models with direct spark ignition and icon control system
Hide thumbs Also See for EF120T4003NA3:
Table of Contents

Advertisement

Thermostat Circuit Testing and Replacement
Continued from previous page.
Condition: Water heater not operating. Digital
display shows error code 80 high water
temperature (over 200°F) (continued from
previous page).
Once cause of overheating condition
has been diagnosed and corrected, the
control board may be reset.
Reconnect and switch on power to the water heater.
Press button under "Reset" and hold for 3 seconds.
Set thermostat to the desired setting.
Water heater will start.
Monitor temperatures for one complete heating cycle making
sure the maximum tank temperature remains below 207°F.
Service Procedure I:
23
WARNING
DO NOT operate the water heater without
verifying that the overheating condition has
been corrected.
23