Definition
Error Code
of Code
Water
temperature
172
sensor
resistance
invalid
NOTE
Cause of Problem and Actions Taken to Correct
Hold 93 will be displayed if this value remains out of range
Measure the resistance of the water temperature sensor and compare it with the tank
temperature using the chart below.
If there is do display, check primary/secondary voltage
Before troubleshooting always verify the following
o
Gas inlet pressure
o
Static to dynamic gas pressure drop
o
No vent and intake restrictions
o
All wire connections are tight
o
No grounded wires or missing grounds
o
No water leaks