Volvo Penta TAMD71B Instruction Manual page 27

Marine genset engine
Hide thumbs Also See for TAMD71B:
Table of Contents

Advertisement

No. Action
8.
Get authorized personnel to
check injectors.
9.
Check batteries.
10. Top up anti-corrosive agent
in freshwater system.
11.
Clean cooling system.
Change coolant.
Intervals
Instructions
2000 hours
Hand in injectors to authorized service deal-
er (or replace with adjusted injectors). Tight-
ening torques: Injectors 50 Nm (5 kpm/ 36.8
lb.ft.), pressure pipes 15–25 Nm (1.5–2.5
kpm/11.0–18.4 ft.lb.).
500 hours
Use protective goggles! Battery fluid ap-
prox. 10 mm (0.39") over cell plates.
WARNING! The batteries contain ox-
yhydrogen gas and extremely corro-
sive sulfuric acid. Naked flames/
sparks close to batteries may cause
an explosion.
500 hours
Add 1/2 liter anti-corrosion agent to the
freshwater system (P/N 1141526-2). NOTE!
: Only when glycol is not used in the cool-
ing system.
12 months
Close the water inlet and drain the water
from the raw water and freshwater
systems. Flush via holes for drain cocks
and plugs until clean water runs out.
Info.
chap.
11.7.1
4.3
10.5.2
5.8
10.5.2