No. Action
4.
Check/drain extra fuel
filter(s).
5.
Replace insert(s) in extra
coarse fuel filter.
6.
Vent fuel system.
7.
Replace switchable fuel fil-
ters
Intervals
Instructions
50 hours
A few hours after stopping en-
gine: Drain off water or contami-
nants through cock/plug (5).
1000 hours
Close the fuel cocks at the tank before
dismantling the single filter or replacing the
inserts of the double filter with the engine
off.
2000 hours
Open vent screws (1). Pump with hand
pump (2) until no air bubbles are visible in
the fuel. Close screw while fuel is flowing
out. Then pump a further 10–20 times.
Check for leaks.
2000 hours
Lever (2) on right – replace left filter. Lever
up – vent left filter. Vent screws (1). Re-
place the right filter in the same way.
Info.
chap.
9.8.1
5
9.8.2
9.8.4
9.8.3