(2) Functions available when setting the unit number to 01–03 or AL (07 in case of wireless remote controller)
• When setting functions for an indoor unit in an independent system, set the unit number to 01 referring to 4 setting the
indoor unit number of Operating Procedure.
• When setting functions for a simultaneous- Twin Triple indoor unit system, set the unit number to 01 to 03 for each indoor
unit in case of selecting different functions for each unit referring to 4 setting the indoor unit number of Operating Procedure.
• When setting the same functions for an entire simultaneous Twin Triple-indoor unit system, set refrigerant address to AL (07
in case of wireless remote controller) referring to 4 setting the indoor unit number of Operating Procedure.
Function
Filter sign
100 h
2500 h
No filter sign indicator
Air flow
Quiet
(Fan speed)
Standard
High ceiling
No. of air outlets
4 directions
3 directions
2 directions
Optional high efficiency
Not supported
filter
Supported
Vane setting
No vanes (Vane No. 3 setting: PLA only)
Vane No.1 setting
Vane No.2 setting
3D i-see Sensor
Position 1 ("□" stamp position)
positioning
(Position 2)
Position 3 ("□" stamp position)
Optional humidifier
Not supported
(PLA only)
Supported
Vane differential setting
No.1 setting (TH5: 24–28:)
in heating mode
No.2 setting (Standard, TH5: 28–32:)
(cold wind prevention)
No.3 setting (TH5: 32–38:)
Swing
Not available Swing
Available
Set temperature in
Not available
heating mode (4 deg-up)*
Available
Fan speed during the
Extra low
heating thermo-OFF
Stop
Setting fan speed
3D i-see Sensor ceiling
Low ceiling
height setting
Standard
High ceiling
Fan speed during the
Setting fan speed
cooling thermo-OFF
Stop
Extra low
Detection of abnormality of
Available
the pipe temperature (P8)
Not available
*PKA-HAL/KAL: 2 deg-up
PEAD-RP
JA(L)Q
Function
Filter sign
100h
2500h
No filter sign indicator
External static pressure 35/50/70/100/150Pa
External static pressure 35/50/70/100/150Pa
Set temperature in heating
Available
mode ( 4 deg up )
Not available
Fan speed during the
Extra low
heating thermo OFF
Stop
Set fan speed
Fan speed during the
Set fan speed
cooling thermo OFF
Stop
Detection of abnormality
Available
of the pipe
Not available
Mode No.11
Setting No.
Settings
Vane No.3 setting
1
No Vanes
2
Vane No.1 setting
3
Vane No.2 setting
* Be careful of the smudge on ceiling.
OCH645
Mode
Setting
Settings
No.
No.
1
07
2
3
1
08
2
3
1
09
2
3
1
10
2
1
11
2
3
1
12
2
3
1
13
2
1
14
2
3
}
1
PLA-EA
23
Wave air flow
2
1
24
2
1
25
2
3
1
26
2
3
1
27
2
3
1
28
2
Setting
Mode
Settings
No.
No.
07
08
10
24
25
27
28
PLA-EA
Less smudging
( Downward position than the standard )
Standard
Less draft * (Upward position than the standard) Less draft * (Upward position than the standard)
Initial setting (factory setting) ─: Not available
4-way
Ceiling
Wall mounted
cassette
suspended
PLA-EA
PCA-KAQ
PKA-HAL
: Initial setting
External static
( Factory setting )
pressure
1
35Pa
2
50Pa
70Pa
3
100Pa
Refer to the right table
150Pa
Refer to the right table
1
2
1
2
3
1
2
1
2
No vane function
Standard
84
Floor
Ceiling
standing
concealed
PKA-KAL
PSA-KA
PEA-GA
Setting No.
Initial setting
( Factory setting )
Mode No. 08 Mode No. 10
2
1
1
3
2
1
2
2
3
2
PCA-KAQ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents