Advertisement

PUHZ-ZRP200YKA2.UK
SYMBOL
NAME
TB1
Terminal Block <Power Supply>
TB2
Terminal Block <Indoor/Outdoor>
MC
Motor for Compressor
MF1, MF2
Fan Motor
21S4
Solenoid Valve (Four-Way Valve)
63H
High Pressure Switch
TH3
Thermistor <Liquid>
TH6
Thermistor <2-Phase Pipe>
TH7
Thermistor <Ambient>
TH8
Thermistor <Heat Sink>
TH32
Thermistor <Comp. Surface>
LEV-A
Linear Expansion Valve
ACL4
Reactor
DCL
Reactor
RS
Rush Current Protect Resistor
FUSE1, FUSE2
Fuse <T15AL250V>
CY1, CY2
Capacitor
C. B.
MF1
1
CNF1
7
(WHT)
MS
3~
1
CNF2
MF2
7
(WHT)
MS
3~
1
2
3
CNDC
(PNK)
CNS
(WHT)
3
1
TB2
S1
S2
TO
INDOOR
UNIT
S3
TB1
L 1
POWER
L 2
SUPPLY
3N ~
400V 50Hz
L 3
N
M-NET ADAPTER
SYMBOL
TB7
Terminal Block <M-NET connection>
CN5
Connector <Transmission>
CND
Connector <Power Supply>
CN2M
Connector <M-NET communication>
OCH645
PUHZ-ZRP250YKA2.UK
SYMBOL
P.B.
Power Circuit Board
TB-U/V/W
Connection Terminal <U/V/W-Phase>
TB-L1/L2/L3
Connection Terminal <L1/L2/L3-Power Supply>
TB-P1/P3
Connection Terminal
X52CA/B
52C Relay
N.F.
Noise Filter Circuit Board
LI1/LI2/LI3/NI
Connection Terminal <L1/L2/L3/N-Power Supply>
LO1/LO2/LO3
Connection Terminal <L1/L2/L3-Power Supply>
GD1, GD2
Connection Terminal <Ground>
C.B.
Controller Circuit Board
Switch <Manual Defrost, Defect History,
SW1
Record Reset, Refrigerant Address>
SW4
Switch <Test Operation>
SW5
Switch <Function Switch, Model Select>
SW6
Switch <Model Select>
SW7
Switch <Function Switch>
SW8
Switch <Function Switch>
63H
LEV-A
TH32
TH7
TH6
TH3
t° t°
1 2
1
4
1 2
1
TH32
TH7/6
TH3
LEV-A
(BLK)
(RED)
(WHT)
(WHT)
1 3
63H
(YLW)
CN2
TRANS
(RED)
1
7
7
F3
CNAC
(WHT)
1
2
F4
21S4
(GRN)
3
4
TH8
P.B.
1 2
CN6
(WHT)
V W
U
MS
3~
MC
CNAC1
(WHT)
1
3
LI1
RED
LI2
WHT
LI3
BLK
NI
BLU
GD1
GD2
N.F.
NAME
NAME
SYMBOL
SW9
SWP
CN31
CN3S
CNDM
CN51
SV1
SS
CNM
CNMNT
CNVMNT
LED1, LED2
F3, F4
X51, X52, X54
M
3
5
* 1
* 1
5
1
3
1
5
CNVMNT
CNMNT
(WHT)
(WHT)
1
14
CNM
(WHT)
CN4
CN31
(WHT)
1 2
CN3S
(WHT)
2
CNDM
(WHT)
1
CN51
(WHT)
1
3
1
3
1
3
SV1
SS
(GRY)
(WHT)
21S4
7
2
2
1 2
1
7 1 2
CN5
CN2
CN4
(RED)
(RED)
(WHT)
BLK
BLK
L3OUT
TB-L3
X52CB
WHT
RED
RED
RS
RED
TB-L1
X52CA
DCL
2
CNCT
CNAC2
(RED) 1 2
1
3
(RED)
LO1
LO2
LO3
CNDC
1
3
3
1
CNL
(PNK)
(BLU)
2
17
NAME
Switch <Function Switch>
Switch <Pump Down>
Connector <Emergency Operation>
Connector <Connection for Option>
Connector <Connection for Option>
Connector <Connection for Option>
Connector <Connection for Option>
Connector <Connection for Option>
Connector <Connection for Option>
Connector
<Connect to Optional M-NET Adapter Board>
Connector
<Connect to Optional M-NET Adapter Board>
LED <Operation Inspection Indicators>
Fuse <T6.3AL250V>
Relay
When M-NET adapter is connected
5
CN5
(WHT)
5
1
M-NET ADAPTER
2
CN2M
CND
(WHT)
(WHT)
1
3
1
3
A B S
1
3
TB7
M-NET
1
3
5
*1. MODEL SELECT
The black square (■) indicates a switch position.
MODEL
SW6
SW5-6 *2
ON
ON
OFF
OFF
200Y
1 2 3 4 5 6 7 8
1 2 3 4 5 6
ON
ON
OFF
OFF
250Y
1 2 3 4 5 6 7 8
1 2 3 4 5 6
*2. SW5-1 to 5: Function switch
RED