< Function setting switch 1
This is used to select the operations of the AW-EX500.
Before changing a setting, the power must be turned off.
The setting items are shown below.
ON
0
PB302
9
8
PB302
7
YR-YB-Y
6
YR-YB-Y
5
4
ADDITIONAL IF
3
756mV
N
2
O
1
714mV
YR-YB-Y
YR-YB-Y, YC
SDI
1: Input signal setting 1 <SDI/ANALOG>
Set this to match the input signals which will be used.
2: Input signal setting 2 <YR-YB-Y, YC/VIDEO>
3: Input signal setting 3 <YR-YB-Y/YC>
Input signal settings 2 and 3 take effect when
<ANALOG> has been selected as input signal setting 1.
OFF
SW NO
PB310
ADDITIONAL I/F SEL
PB310
OPTION I/F SEL
RGB
PB302 OUT SEL (ADD) 8
RGB
PB302 OUT SEL (OPT)
OPTION IF
RS232C SEL
525mV
INPUT LEVEL R-YB-Y
700mV
INPUT LEVEL Y
YC
INPUT SEL3
VIDEO
INPUT SEL2
ANALOG
INPUT SEL1
(Factory setting: ANALOG)
(Factory setting: VIDEO)
(Factory setting: YC)
Set as shown below to match the analog signals which
are to be input to analog video input connectors 5, 6
and 7.
INPUT SEL2
VIDEO
VIDEO
0
9
YR-YB-Y, Y/C
YR-YB-Y, Y/C
7
6
4: Input signal level setting Y <714mV/700mV>
5
4
3
When analog component signals have been selected
2
as the input signals, select this setting by determining
1
whether the white 100% signal level of the input
signals is 714mV or 700mV.
When VIDEO signals or YC signals are to be input, set
to 700mV.
5: Input signal level setting R-YB-Y <756mV/525mV>
When analog component signals have been selected
as the input signals, select this setting by determining
whether the color signal level of the input signals is
756mV or 525mV.
When VIDEO signals or YC signals are to input, set to
525mV.
- 9 -
INPUT SEL3
Input signal
Y/C
VIDEO
YR-YB-Y
VIDEO
Y/C
Y/C
YR-YB-Y
YR-YB-Y
(Factory setting: 700mV)
(Factory setting: 525mV)