Default Temperature; Device Name; System Down Set Voltage; System Down Set Voltage Time - Texas Instruments BQ27220 Technical Reference Manual

Hide thumbs Also See for BQ27220:
Table of Contents

Advertisement

Functional Description

4.9.67 Default Temperature

This is the temperature used to initialize the Temperature() register until the host writes a different value if the
Operation Config A [WRTEMP] bit is set.

4.9.68 Device Name

The DeviceName() function returns a string stored in DeviceName(). This is a string data with maximum text
length of 7 characters. This field does not affect operation, nor is it used by the device. It is read by using the
extended data command: DeviceName() (0x63 through 0x69).

4.9.69 System Down Set Voltage

The BQ27220 device goes into SYSTEM DOWN mode if the battery pack Voltage() is equal to or less than
SysDown Set Voltage Threshold for SysDown Set Volt Time.

4.9.70 System Down Set Voltage Time

The BQ27220 device goes into SYSTEM DOWN mode if the battery pack Voltage() is equal to or less than
SysDown Set Threshold for SysDown Set Time.

4.9.71 System Down Clear Voltage

The BQ27220 device goes into SYSTEM DOWN CLEAR mode if the battery pack Voltage() is equal to or above
SysDown Clear Voltage Threshold.

4.9.72 Full Reset Counter

The counter increments on a full reset event.

4.9.73 Reset Counter Watchdog

The counter increments on a watchdog reset event.
62
BQ27220
Copyright © 2022 Texas Instruments Incorporated
SLUUBD4A – APRIL 2016 – REVISED NOVEMBER 2022
Submit Document Feedback
www.ti.com

Advertisement

Table of Contents
loading

Table of Contents