CONNECTING LN-10 AND DH-10 TO THE FLEXTEC 350XP CCC
FLEXTEC 350XP CCC
WELD MODE
WELD TERMINALS
REMOTE/LOCAL
VOLTMETER POLARITY
LN-10,DH-10 Control Switch Setup
Initial set up of the LN-10, DH-10 control for the system
components being used and for general operator preferences
is done using a pair of 8-pole DIP switches located inside the
LN-10, DH-10 control box.
Setup DIP Switch Access
1) Shut off the input power to the LN-10, DH-10 control by
turning off the power at the welding power source it is
connected to.
2) Remove the two screws on the top of the LN-10, DH-10
control box door and swing the door down to open.
3) Locate the two 8-pole DIP switches, near the top left corner
of the LN-10, DH-10 Control P.C. board, labeled S1 and S2.
4) Switch settings are only programmed during input power-up
restoration.
14-PIN CONTROL CABLE K1501-XX
ELECTRODE
WORK
CONTROL SETTING
A-12

WIRE FEEDER

LN-10
DH-10
CV, CV-INNERSHIELD
REMOTELY CONTROLLED
REMOTE
PROCESS DEPENDENT
Setting the DIP Switches
The DIP switches are each labeled with an "ON" arrow showing
the on direction for each of the 8 individual switches in each DIP
switch (S1 and S2). The functions of these switches are also
labeled and set as described below:
Pwr Sources
Head
S1
ON
1
2
3
4
5
6
7
8
S1
INSTALLATION
Pwr Sources
S1
ON
1
2
3
4
5
6
7
8
S1