4. Press the green "ENGINE START" button. The "Prestart" screen will be displayed (if equipped) and a countdown
will begin from 20 seconds to 0.
5. The "Starting" screen will be displayed. The engine will crank and start running.
6. The "Running" screen will display.
Note: It may take a few seconds for the engine to run smoothly and reach its governed operating speed. The 45
second "V Detect" time delay will start to countdown.
OFF MAN AUT
7. The LCD window will then toggle from the "Running" screen to the generator display screen and then to the
engine display screen.
8. If the engine does not start after the first cranking attempt, the engine will pause for 15 seconds to allow the
starter to cool. The LCD window will show "PAUSE". The engine will make two more attempts to start for a total
of three crank cycles.
9. Should the engine not start and run within three starting cycles, the LCD window will show "SD Start fail". The
starting sequence may be repeated after the starter has had a minimum of two minutes to cool. Press the "FAULT
RESET" button to clear the controller. To start the unit, press the green "ENGINE START" button.
Note: The engine controller may skip the preheat engine steps on some of the larger models.
10. Once the engine starts it will immediately begin speeding up to a constant 1800 rpm. The engine may hunt or
change speeds until operating speed is reached. After a few minutes of operation, the engine will be warmed