Model Number Identification; Specifications / Electrical Data - Lennox CBX40UHV Series Unit Information

Hide thumbs Also See for CBX40UHV Series:
Table of Contents

Advertisement

MODEL NUMBER IDENTIFICATION

Unit Type
CB = Air Handler
Refrigerant Type
X = R−410A
Series
Configuration
UHV = Up−Flow/Horizontal, Variable
Speed Blower Motor
Nominal Cooling Capacity

SPECIFICATIONS / ELECTRICAL DATA

Refer to the Unit Engineering Handbook or Lennox Price Book for optional accessories for this unit.
SPECIFICATIONS
GENERAL DATA
Nominal cooling capacity − tons
Connections
in.
Indoor
Coil
Blower Data
Wheel nominal diameter x width − in.
Filters (MERV16)
Shipping Data − 1 Package − lbs.
ELECTRICAL DATA
Voltage − phase − 60hz
2
Maximum overcurrent protection (unit only)
Minimum circuit ampacity (unit only)
1
Disposable frame type filter.
2
HACR type circuit breaker or fuse.
REPLACEMENT CIRCUIT BREAKERS
Voltage
208/240V − 1 Phase
208/240V − 3 Phase
CB X 40 UHV − 036 − 230 − 6 − 02
024 = 2 tons
030 = 2.5 tons
036 = 3 tons
042 = 3.5 tons
048 = 4 tons
060 = 5 tons
MODEL NUMBER
Refrigerant
Suction (vapor) line − sweat
Liquid line − sweat
Condensate drain (fpt)
2
Net face area − ft.
Tube outside diameter − in.
Number of rows
Fins per inch
Motor output − hp
1
Size − in.
Description
Catalog No.
25 amp, 2 pole
41K13
30 amp, 2 pole
17K70
35 amp, 2 pole
72K07
40 amp, 2 pole
49K14
45 amp, 2 pole
17K71
50 amp, 2 pole
41K12
60 amp, 2 pole
17K72
30 amp, 3 pole
18M85
40 amp, 3 pole
41K16
45 amp, 3 pole
18M86
50 amp, 3 pole
41K15
60 amp, 3 pole
41K17
Minor Revision Number
Refrigerant Metering Device
2 = Fixed Orifice
3 = TXV − Bleedport (indoor unit)
4 = TXV − Non−bleedport (indoor unit)
5 = TXV − Non−bleedport (outdoor unit)
6 = TXV − R−410A Non−bleedport (indoor unit)
Voltage
230 = 208/230V−60hz−1ph
CBX40UHV
CBX40UHV
CBX40UHV
-024
-030
2
2.5
HFC−410A
HFC−410A
HFC−410A
3/4
3/4
3/8
3/8
(2) 3/4
(2) 3/4
(2) 3/4
5.0
5.0
3/8
3/8
3
3
12
12
11 X 8
11 X 8
11 X 8
1/2
1/2
20 X 20 X 5
20 X 20 X 5
20 X 20 X 5
165
167
15
15
5
5
NOTE − Electric Heat Circuit Breakers are sized for 240VAC operation. Electric
heaters operating at voltages other than 240VAC may require the factory installed
circuit breaker be replaced with a field installed circuit breaker. See Maximum
Overcurrent Protection column in the Electric Heat Tables to determine if a circuit
breaker change is required.
Page 2
CBX40UHV
CBX40UHV
-036
-042
-048
3
3.5
4
HFC−410A
HFC−410A
3/4
7/8
7/8
3/8
3/8
3/8
(2) 3/4
(2) 3/4
5.0
7.22
7.22
3/8
3/8
3/8
3
3
3
12
12
12
11−1/2 X 9
11−1/2 X 9
3/4
1
1
20 X 25 X 5
20 X 25 X 5
172
214
216
208/230V−1PH
15
20
20
10
10
10
CBX40UHV
-060
5
HFC−410A
7/8
3/8
(2) 3/4
7.22
3/8
3
12
11−1/2 X 9
1
20 X 25 X 5
216
20
10
CBX40UHV