Pre-Start-Up Checks
1. Disconnect and lock-out all power switches to fan.
2. Check all fasteners on the ceiling mount, mounting
kit, blades, motor driver, motor and accessories for
tightness.
3. Rotate the fan impeller by hand to ensure that it
rotates freely and does not come into contact with
any obstructions.
4. Check all electrical connections for proper
attachment.
5. Verify that the fan is hanging so that the airfoils
and downtube are level and the fan is plumb to
the floor. Adjust guy wire tension as necessary (if
applicable).

RF Remote Control Operation

NOTE: The RF remote control has a maximum range of
roughly 20-25 feet.
Button
0
1-6
0 +
12
Overhead Ceiling Fans
Function
Press the 0 button to turn off the
fan. The fan will produce a short
beep to confirm that an off signal
has been received.
Press the 1-6 buttons to turn on
the fan and set fan speed with
speed increasing in numerical
order (1 = lowest speed, 6 =
highest speed). The fan will
produce a short beep to confirm
that a run command signal has
been received.
Press the rotation button to change
the fan's direction of rotation. In the
forward direction, the fan will move
air downwards (counterclockwise
rotation when viewed from below).
In the reverse direction, the fan
will move air upwards (clockwise
rotation when viewed from below).
The fan will produce a short beep
to confirm that a rotation command
signal has been received.
Press the 0 and the settings
buttons at the same time to
enter pairing mode. Refer to the
instructions below to pair the RF
remote control with a fan.
RF Remote Control Pairing (Single Fan)
NOTE: Each fan includes an RF remote control that
is paired with its motor driver at the factory prior to
shipment. The following instructions should only be
followed if the RF remote control is not communicating
with the fan.
1. Confirm that power wiring has been installed
according to the instructions on page 11.
2. Apply power to the fan. The pairing process must
be completed within 1 minute of power being
applied.
3. Press and hold the 0 and
seconds while pointing the RF remote control at
the fan that needs to be paired. Please note that
the RF remote control has a maximum range of 20-
25 feet.
4. The fan will produce two short beeps to confirm
that it has been paired with the RF remote control.
5. If no sound is heard, then pairing has failed. Turn
off power to the fan and wait 1 minute before
repeating steps 2 through 4 to reattempt pairing
with the fan.

RF Remote Control Pairing

(Multiple Fans)

NOTE: Each fan includes an RF remote control that
is paired with its motor driver at the factory prior to
shipment. The following instructions should only be
followed if multiple fans will be operated using one RF
remote control.
IMPORTANT: If multiple fans are operated using one RF
remote control, all fans will operate with the same speed
setting and direction of rotation.
1. Confirm that power wiring has been installed
according to the instructions on page 11.
2. Apply power to the first fan that should be paired
with the RF remote control. The pairing process
must be completed within 1 minute of power being
applied.
3. Press and hold the 0 and
seconds while pointing the RF remote control at
the fan that need to be paired. Please note that the
RF remote control has a maximum range of 20-25
feet.
4. The fan will produce two short beeps to confirm
that it has been paired with the RF remote control.
5. If no sound is heard, then pairing has failed. Turn
off power to the fan and wait 1 minute before
repeating steps 2 through 4 to reattempt pairing
with the fan.
6. After successfully pairing the RF remote control,
turn off power to the fan.
7. Repeat steps 2-6 for all remaining fans.