2.1 CONDENSATE DRAIN CONNECTION

The condensate output and electrical connections can be at either end of the machine, at the
side or in the back, depending on the requirements of the user. To gain access to the unit
remove the covers, unscrewing the fixing screw in both end mouldings.The driptray can be
removed and turned round. Remove the desired knockouts, insert grommet (supplied) and
route condensate pipe through the knockout.(Tube outside diameter 19mm).
REMOVAL OF COVERS
CONDENSATE
DRAIN
CONDENSATE
DRAIN
L
22.00
40.00
22.00
40.00
DH66 DEHUMIDIFIER SHOWN.
POSITIONS OF KNOCKOUTS FOR CONDENSATE DRAIN CONNECTION
Page 5
SD496260 ISSUE 10