Outdoor Unit
SAP – C91GHA
Controller PCB
Compressor
Type
Compressor model
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Safety devices
Run capacitor
Crank case heater
Fan & Fan Motor
Type
Q'ty ... Dia.
Fan motor model ... Q'ty
No. of poles ... rpm (230 V, High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Safety devices
Run capacitor
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
External Finish
Type
Overload relay
Operating temp.
Open
Close
Operating amp.(Ambient temp. 25°C)
Type
Operating temp.
Open
Close
W
cc
4GSD-T or SAY-56T ... 550
External(OLR A)
MRA99057-9201
°C
145±5
°C
69±11
Trip in 6 to 16 sec. at 18A
µF
VAC
UE6-21AH5PC-S ... 1
W
°C
°C
µF
VAC
Aluminum plate fin / Copper tube
mm
m
2
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
9
POW-C96GH-S
Rotary (Hermetic)
C-R92H5W 80692945-S
900
C–R : 3.07
C–S : 7.97
External(OLR T)
CS-7C115
22.5
400
Propeller
1 ... ø370
6 ... 760
20
WHT-BRN : 338.3
WHT-PNK : 389.7
Thermal fuse
145 ± 2
1.5
440
1
1.2
0.333
115±3
95±5