Komatsu 06253 Operation & Maintenance Manual page 265

Hydraulic mining shovel
Table of Contents

Advertisement

MAINTENANCE
Extended Service Intervals for Engines with
Engine Oil Management System
Reserve System Oil Flow Schematic, illust. Z23083
(3)
Oil filters for the engine oil reserve system
(4)
Suction line from reserve tank
(5)
Suction line to pumping unit
(6)
Supply line from pumping unit to crankcase
(7)
Withdrawal oil line from engine oil pan to pump
(8)
Ventilation line for reserve tank
(11)
Oil feed-back line to reserve tank
(12)
Pumping unit, located on the cross member below the fire wall. The pump
unit works automatically as soon as the engine speed is above 300 RPM.
The pump unit consists of a pumping element for feeding oil from tank (13)
into the engine oil pan. The second pumping element withdraws oil from
the engine oil pan and feeds it back into the reserve tank when the oil level
in the oil pan exceeds the maximum running oil level. The combined oper-
ation of the pumping elements maintains an optimal oil level in the engine
oil pan. Oil drawn off by the Centinel burn system is also replaced through
the supply system "Reserve".
(13)
Reserve oil tank. The reserve oil tank is an integrated part of the main
frame cross member.
(14)
Drain plug
(15)
Cross member below the fire wall
(16)
Plug. On shovels with KIM Hot start heating system a thermostat is
installed in place of plug (16).
(17)
Oil level sight gauge. Be sure to add engine oil via the swing down service
arm before the oil level is at the MIN marking on the sight gauge.
(18)
Refilling line from swing down service arm
4.6 LUBRICATION AND MAINTENANCE SCHEDULE
265